background image

Thank you for purchasing the Radii Plus LED curing light. The Radii Plus is a 

powerful, cordless, lightweight curing light using an LED for the polymerization of 

composite restorative materials that contain the photo-initiator Camphorquinone. 

The Radii Plus produces a strong blue light in the wavelength range of 440 – 480 

nm, the relevant range for Camphorquinone containing products. The Radii Plus 

features a ‘NO RAMP’ mode and ‘RAMP’ mode for convenient polymerization 

shrinkage minimization of composite materials. In addition to this, the 

LED attachments can be changed depending on the clinical application. 

Product coNtENtS LISt

•  Handpiece (battery pack, control section and standard LED attachment)

•  Charger

•  Plug pack

•  100 Radii Plus barrier sleeves 

•  3 Radii Plus lens caps  

•   Radii Plus light shields (5 Pack)

uNPackINg aNd INItIaL cHargINg

The Radii Plus has been carefully packed to withstand any damage during transit. 

Ensure all parts contained within the box match the product contents list above.

1) Remove all parts from the box.  

2) Place the plug pack cable into the charger.

3) Fix the correct adapter head onto the plug pack.

4) Plug the plug pack into an available power outlet and turn power outlet on. 

The charger will conduct a brief LED test: the charge light LED should momentarily 

show red/green and the 5 blue radiometer LEDs should turn on/off.

5) Place the curing light handpiece into the charger. The handpiece can be rotated 

360º in the charger. Depending on the length of time from manufacture to 

package opening, the charge remaining in the battery can vary. The charge light 

will show the below three conditions.

   

  

Charge Light Color 

Battery condition

  

Red 

 

discharged 

 

 

Flashing Green 

charging (OK to use) 

 

 

Green 

 

charged 

To ensure the highest level of performance, allow the Radii Plus to fully charge 

prior to first use. On average, it will take approximately 1-3 hours to initially charge 

the Radii Plus.

oPEratIoN

• Turning unit on and off

Simply pick up the curing light handpiece, press the on/off button once to activate 

and de-activate the light. Audible beeps facilitate accurate time measurement of 

curing.  Replace the Radii Plus back in the charger when not in use.

• NO RAMP mode and RAMP mode.

The Radii Plus has two curing modes, NO RAMP and RAMP mode. NO RAMP mode 

will output 100% intensity immediately after pressing the on/off button whereas 

RAMP mode will output a reduced intensity for the first 5 seconds before 

irradiating at 100% intensity.

• Switching between the NO RAMP mode and RAMP mode.

The Radii Plus has been set at the factory to the NO RAMP mode. To switch 

between the NO RAMP mode and RAMP mode, when the Radii Plus is off, hold 

down the on/off button for 3 seconds. Two audible beeps will be heard. The unit 

will now be programmed for RAMP mode. To switch back to the NO RAMP mode, 

hold down the on/off button for 3 seconds,  a single audible beep will be heard 

indicating the unit has switched back to NO RAMP mode. NOTE: In RAMP mode 

the visible light starts slightly dimmer and progressively gets stronger, as opposed 

to in NO RAMP mode, where the visible light is constant from the start.

RAMP mode indicator:  

This unit has been fitted with a blue indicator light above the on/off button.  

When in RAMP mode, the indicator light will show blue. The indicator light is 

off in the NO RAMP mode.

• Audible beeps for NO RAMP and RAMP modes:

Depending on the mode set (NO RAMP or RAMP), the beeping cycle will differ. 

Below is a table explaining the audible beeps for each mode.

audible beeps  

time between beeps      total elapsed time

 

 

 (seconds) 

 (seconds) 

CURE MODE   

NO RAMP 

RAMP 

NO RAMP 

RAMP

1 short beep   

10 sec 

15 sec 

10 sec 

15 sec

2 short beeps  

10 sec 

10 sec 

20 sec 

25 sec

3 short beeps  

10 sec 

10 sec 

30 sec 

35 sec

4 short beeps  

10 sec 

10 sec 

40 sec 

45 sec

5 short beeps  

10 sec 

10 sec 

50 sec 

55 sec

1 long beep   

10 sec 

10 sec 

60 sec 

65 sec

At the end of 60 seconds (or 65 seconds in case of “RAMP” mode) one long beep 

will be heard before the blue LED is automatically switched off. 

NOTE: The above cycle is based on the Standard LED attachment supplied in this 

kit. Other access types of LED attachments from SDI will have different cycles. Refer 

to instruction sheets associated with those products for beeping cycle. 

• Rotating and changing the LED attachment

The LED attachment, can be rotated 360º to ensure accurate and detailed 

polimerization in any area of the mouth. 

WARNING: Do not rotate the LED attachment at the LED end, instead turn at the 

end closer to the control section as shown below:

• Lens Cap

The Radii Plus has been supplied with a lens cap fitted. The lens cap should be 

inspected prior to each use for scratches, cracks or foreign matter that may reduce 

the effectiveness of the LED light source. Generally lens caps should be replaced 

every 2 weeks. To remove the lens cap carefully unscrew the old lens cap counter-

clockwise and fit the new lens cap by tightening clockwise.

• Built in Radiometer

The Radii Plus’s built-in radiometer provides a simple test to check the

functionality of the unit. With the Radii Plus on, carefully position the lens

cap on the built-in radiometer. 4 or 5 lights should illuminate indicating a

fully functional unit. If only 1,2 or 3 lights illuminate, it could be due

to the following reasons:

1) There could be some material on the lens cap such as composite: - the

lens cap should be replaced.

2) The lens cap could be damaged or cracked: - it should be replaced.

3) The battery could be extremely low - the unit should be recharged.

4) In a severe case the light could be malfunctioning: - the unit should be serviced.

Note:

  Portable radiometers can give inaccurate and inconsistent results.   These 

results can vary by as much as 300 mW/cm

2

 or more.

• Disposable barrier sleeves

Transparent, disposable barrier sleeves are supplied to protect the handpiece and 

prevent cross contamination.  Testing showed no significant difference in spectral 

and energy output when operating with or without a barrier sleeve in place.

radii plus

INSTRUCTIONS FOR USE

Slide the barrier sleeve over the end of the handpiece before placing the orange 

light shield on the end of the handpiece.

It is essential to use disposable barrier sleeves to prevent any liquids 

getting on the handpiece. Evidence of liquids entering handpiece causing 

damage due to not using barrier sleeves will void warranty.

• Automatic shut off function using the standard LED attachment
Should the Radii Plus standard LED attachment become too hot due to 

excessive use (after about 4 minutes of continuous irradiation),  the unit will 

automatically shut off and be un-usable for about 1 minute until it cools down. 

If using a different LED attachment, please refer to the instruction sheet for that 

attachment’s automatic shut-off sequence as it may vary. 

• Changing the LED Attachment

The Radii Plus allows you to change the LED attachment depending on the curing 

situation. To change the LED attachment, pull off the LED attachment carefully by 

placing fingers as shown below. Please refer to LED attachment instructions for use  

for operation guidelines.

• Changing the battery pack

Carefully unscrew the battery pack counter-clockwise to remove and replace. A 

single beep will be heard when the battery pack is successfully connected. 

• Cleaning the Radii Plus: 

The ideal way to protect patients from cross-infection is to utilise Radii Plus barrier 

sleeves. Barrier sleeves are also essential to keep the Radii Plus clean. When 

cleaning the Radii Plus handpiece, ensure lens cap, battery pack, control section 

and LED attachment are connected as one unit.

•  LIQUID CONTACT WITH TERMINALS OF  

 

HANDPIECE AND CHARGER WILL CAUSE  

 

DAMAGE VOIDING WARRANTY.

•  LIQUID CONTACT WITH LED WILL CAUSE  

 

DAMAGE VOIDING WARRANTY.

•   LIQUIDS MUST NOT ENTER ANY PART OF THE  

 

HaNdPIEcE or cHargEr.

•   DO NOT SPRAY LIQUIDS DIRECTLY ONTO, OR  

 

APPLY COPIOUS AMOUNTS OF LIQUIDS TO  

 

tHE radII PLuS.

•   DO NOT AUTOCLAVE THE RADII PLUS.

• General Surface Cleaning

General surface cleaning can be conducted with anti-microbial  

 

surface disinfectant such as Glutaraldehyde, Chlorhexidine  

 

gluconate, and 70% Isopropyl alcohol. When applying the  

 

disinfectant to any component of the device, spray the disinfectant    

agent onto a piece of cloth and wipe over the 

external

 areas to be    

cleaned.

• Curing Times

Curing times will differ for different formulations of composite restorative 

materials. Follow the manufacturers instructions for recommended curing times.   

Always bench test new materials before use in-vivo.

• Disposal of battery pack

As a means of protecting the environment, the Radii Plus battery pack is fitted with 

a Lithium Ion battery pack. Dispose of battery pack in accordance with local legal 

regulations.

troubLE SHootINg

Problem 

causes  

Solution

• Charge light flashes red   Possible battery fault 

Replace battery 

  
• Handpiece blue LED  

Battery charged too   

Re-charge battery 

   flashes then goes off 

low 

 

 

• audible beep heard 

LED attachment is  

Correctly insert

   but no light irradiates 

not correctly inserted 

LED attachment 

 

 

 

 

(see below) 

 

 

 

 

 

 

 

 

 

 

• No lights appear on the  

1.

 Check terminals on the battery are clean   

   charger when the hand       and free of debris.

   piece is placed on  

2. 

Check power is getting to charger, turn

   the charger. 

    power outlet on . The charge light LED should  

 

 

    momentarily show red/green and the 5 blue  

 

 

    radiometer LEDs should turn on/off.

  

3. 

Check the power outlet is turned on, if so use a  

 

 

    different power outlet.

  

4. 

Check the plug pack is correctly connected to  

 

 

    the charger.

  

5. 

Check that the hand piece is placed into the  

 

 

    charger correctly.

  

6. 

If the problem still exists after checking 1, 2,  

 

 

    3 and 4 above the charger may be faulty. Return  

 

 

    the unit to the supplier for service.

 

When returning faulty units please make sure that all parts are returned together in 

the original packaging.

SAFETY AND PRECAUTIONS

The safe operation of this unit depends on strictly following the operating 

instructions in this manual. The Manufacturer accepts no liability for any damage 

resulting from the use of this unit for any other purpose than the polimerization of 

dental composite materials.

- The equipment can not be exposed or immersed in water or wet locations. The 

equipment does not have protection against liquid penetration.

- Equipment not suitable for use in the presence of flammable anesthetic mixtures 

with air oxygen or nitrous oxide.

 cautIoN! 

 Irradiation of the eyes bears an inherent health risk. Hence,  

 

the light must not be directed towards the eyes. Exposure must be  

 

restricted to the area of the oral cavity in which clinical treatment is  

 

intended. Suitable blue-light filtering safety goggles should be used.  

 

The Radii Plus emits a high intensity light and intensive light exposure of  

 

soft tissues (gingiva, oral mucosa and skin) should be avoided as this  

 

exposure may cause damage or irritation.The emitted light should be  

 

placed directly above the material to be cured.   If applicable cover soft  

 

tissue areas.

 

Do not use the Radii Plus in patients or by users with:

 

•  heart pacemaker implants who have been advised to be  

 

 

    cautious in regards to their exposure to small electrical devices.

 

•  a history of photo biological reactions (including individuals    

 

    with urticaria solaris or erythropoietic protoporphyria) or who are  

 

    currently on photo-sensitizing medication (including 8-methoxypsoralen  

 

    or dimethylchlorotetracycline).

 

•  a history of cataract surgery. These people may be particularly  

 

    sensitive to the exposure to light and should be discouraged from Radii  

 

    Plus treatment unless adequate safety measures, such as the use of  

 

    protective goggles to remove blue light, are undertaken.

 

•  a history of retinal disease. These people should seek advice from  

 

    their ophthalmologist prior to operating the unit. In operating the Radii  

 

    Plus unit, this group of individuals must take extreme care and comply  

 

    with all safety precautions (including the use of suitable light-filtering  

 

    safety goggles).

WARRANTY PERIOD

SDI Limited, the Manufacturer, extends a five (5) year warranty against defects 

in materials or workmanship to the original purchaser of this product, except the 

battery which has a two (2) year warranty. The Manufacturer agrees to correct any 

defects which develop within the warranty period, either by repair or replacement, 

at its option.   This warranty is valid providing factory inspection indicates that any 

such defect developed during normal and proper use subject to the conditions 

below.

WARRANTY CONDITIONS - PLEASE READ CAREFULLY

• 

Please fill out the warranty card included in kit and send promptly  

 

back to SDI with proof of purchase. Failure to do so may void your  

 warranty.

• 

alternatively goto http://www.sdi.com.au/warranty to register your  

 warranty. 

a) Claims for damage in shipment should be filed promptly with the transportation 

company.

b) All shipments claimed defective can only be returned to the Manufacturer 

with the written consent of the Manufacturer. All returned products must be 

accompanied by a full description of discrepancy or malfunction.

c) Only SDI authorized service personnel are allowed to carry out repairs to the 

Radii Plus. Manufacturer shall be released from all obligations under this warranty 

if repairs or modifications are made by persons other than Manufacturer’s own or 

authorized service personnel.

d) Use only SDI parts exclusively to replace defective components. The product 

warranty does not cover any damage resulting from the use of third-party 

replacements parts.

e) Manufacturer shall be released from all obligations under this warranty 

in the event of improper installation; damage due to casualty; or obvious 

misuse including but not limited to damage from liquids and autoclaving.

f) Manufacturer shall in no event be liable for any consequential damages arising 

from the misuse of the product.

g) Only the above stated warranty shall be applicable, and all other warranties, 

expressed or implied, are hereby excluded.

All correspondence concerning the product should specify the model and serial 

number.  

tEcHNIcaL data

Equipment powered internally.

Handpiece (battery, control section and standard LED attachment)

-       wavelength range:         

440 nm – 480 nm

-       peak wavelength range:     

460 nm

-      RAMP mode elapsed time 

 

to full intensity:            

5 seconds

-       light intensity:              

1500 mW/cm

2

 (peak)

-       duration of continuous use 

 

NO RAMP mode:       

60 seconds

 

RAMP mode: 

 

65 seconds

-      total continuous run time

      with fully charged battery:     

3 hours, 20 minutes

-      dimensions:               

22mm diameter x 243mm long

-      weight:                 

 

176g /6.2 ounces

-      battery:                 

 

2 x 4.2V Lithium Ion – 1400 mAh

Plug Pack

-      input voltage:               

90 – 264V – 50/60 Hz

-      output voltage:             

12V DC

-      output current:             

750 mA

-      dimensions:               

70mm high x 45mm wide x 50mm long

-      weight:                 

 

80g / 2.82 ounces        

Charger

-      time to charge battery:       

60 – 180 minutes

-      operating temperature:          

10ºC - 40ºC

-      total height with handpiece

      inserted:                    

255mm

-      dimensions:               

70mm wide x 40mm high x 130mm long

-      weight                 

 

84g / 3 ounces

According to classification IEC 60601-1

REPLACEMENT PARTS AND ACCESSORIES

Replacement parts and accessories which can be installed without special training 

or equipment, can also be obtained from your authorized SDI dealer.

 

 

   Re-order 

Code

Radii Plus replacement lens caps (25 Pack)          

5600054

Radii Plus barrier sleeves (1000 pack)              

5600055

Radii Plus light shield (5 Pack)                     

5600056

Radii Plus Full Arch Bleaching LED attachment    

5600057

Radii Plus Single Tooth Bleaching LED attachment    

5600058

Radii Plus Orthodontic (ortho) LED attachment       

5600059

Radii Plus Standard LED attachment                  

5600060

Radii Plus Replacement Battery Pack                 

5600062

Radii Plus Control Section                           

5600061

Radii Plus Charger (includes plug pack)

 

- Australia/New Zealand 

 

5600063

 

- United Kingdom  

 

 

5600064

 

- North and South America / Asia 

 

5600065

 

- Europe  

 

 

5600066

LED Radiometer 

 

 

5600028  

E

N

G

L

I

S

H

radii plus

CAUTION
(refer to accompanying 
instructions)

Type B Applied Part

Class II Equipment

Transport and storage environment:  
Ambient temperature: 0˚C - 40˚C (32˚F - 104˚F)
Relative humidity: 10% - 85%
Atmospheric pressure: 0.5 atm - 1.0 atm (500 hPa to 1060 hPa)

Charger

Radiometer
indicators

Charge light

LED attachment
Lens cap

Control section

On/off button

X

4

X

4

X

4

Handpiece

Battery pack

Radiometer

Ramp mode indicator

Made in Australia by SDI Limited
Bayswater, Victoria 3153
Australia 1 800 337 003 
Austria 00800 022 55 734 
Brazil 0800 770 1735
France 00800 022 55 734
Germany 0800 100 5759
Ireland 01 886 9577
Italy 800 780625 
New Zealand 0800 734 034
Spain 00800 022 55 734
United Kingdom 00800 022 55 734

USA & Canada 1 800 228 5166
www.sdi.com.au

SDI Dental Limited
Block 8, St Johns Court
Swords Road, Santry
Dublin 9, Ireland
Tel +353 1 886 9577

Last Revised: 10 - 2012