HPDA-15RMi-CW
1-100 MHz ISOLATION AMPLIFIER
OPERATING MANUAL
SPECTRADYNAMICS, INC • 1849 Cherry St. Unit 2 • Louisville, CO 80027
Phone: (303) 665-1852 • Fax: (303) 604-6088
www.spectradynamics.com
S
PECTRA
D
YNAMICS
,
I
NC
Страница 1: ...HPDA 15RMi CW 1 100 MHz ISOLATION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS INC 1849 Cherry St Unit 2 Louisville CO 80027 Phone 303 665 1852 Fax 303 604 6088 www spectradynamics com SPECTRADYNAMICS INC ...
Страница 2: ...HPDA 15RMi CW 1 100 MHz Isolation Amplifier Operating Manual Copyright 2020 SpectraDynamics Inc All rights reserved HPDA 15RMi CW R01 2021 FA MD ...
Страница 3: ... Safety and preparation for use 2 2 1 Electrical 2 2 2 Instrument 3 3 0 Front panel description 4 4 0 Back panel description 5 5 0 Installation 6 6 0 Operation 7 7 0 Troubleshooting 8 8 0 Specifications 9 9 0 Warranty and service 12 ...
Страница 4: ......
Страница 5: ... the corresponding module will turn off indicating a fault condition The HPDA 15RMi CW is designed to be powered by a 100 to 240 VAC mains source or by a 12 to 36 VDC power source The DC power module may be used as a main power source for the instrument or in conjunction with the AC power module as a backup power supply in case of loss of the main AC power The instrument is designed to automatical...
Страница 6: ...ion Only replace fuse with the same type and specifications AC Power The instrument has a detachable three wire power cord for connection to a grounded AC power source The enclosure of the unit is directly connected to the outlet ground to protect against electrical shock Always use an outlet with a protective ground and do not disable this safety mechanism Detaching the AC power cord is the only ...
Страница 7: ...he instrument and voids all warranties 2 2 Instrument Safety and Preparation for Use The HPDA 15RMi CW is designed to distribute RF signals with a frequency of 1 to 100 MHz The recommended level for the RF input signal is 0 dBm to 15 dBm Any output level below 0 dBm will trigger a fault condition turning off the monitor LED for the corresponding RF module Input signals must be kept below 20 dBm as...
Страница 8: ...installed on every HPDA 15RMi CW option Only HPDA 15RMi CW options with 3 modules come with three functioning monitor LEDs All other options will have a non working monitor LED Please refer to HPDA 15RMi CW table options on Page 1 The monitor LEDs will be on if all RF outputs of the corresponding module are greater than 0 dBm RF signal levels less than 0 dBm will trigger a fault condition and the ...
Страница 9: ...ge of 1 MHz to 100 MHz with power level of 13 dBm 2 dBm may be connected to the SMA connector labeled INPUT Part number HPDA 15RMi CW includes three independent RF distribution modules each SMA input provides five buffered copies of the input signal as shown on the picture above Other configurations are available and may be selected by the part numbers shown below OUTPUTS The number of available O...
Страница 10: ...ps with a standard North American or European IEC power cord and a RM12BPE 6S 81 DC connector You may prepare a DC power cable with the DC connector following the connector configuration on page 3 Locate the AC POWER entry module on the rear of the enclosure and connect the power cord You may also connect the optional DC POWER Connector to an appropriate DC power source ...
Страница 11: ...signal has a power level greater than 0 dBm the corresponding monitor LED of the selected module located on the front panel will light up Five buffered copies per distribution module of the RF signal s will be available on the SMA connectors labeled OUTPUTS located on the back panel All outputs are AC coupled and the grounds are DC isolated to reduce the effect of ground loops Make sure that the a...
Страница 12: ...If any fuse is blown replace with same type and rating Please contact SDI if the any of the fuses blow again or if the event that caused the fuse to blow is not known Monitor LEDs are off Check to see if the RF signal provided to the instrument is greater than 0 dBm Check to see if a signal is present at all outputs of the signal distribution module The Monitor LED will remain off with a power lev...
Страница 13: ...0 MHz 0 0 2 0 5 dB Impedance Input Output 50 50 Ohms Return loss Input S11 10 MHz Output S22 10 MHz 35 35 30 30 dB Distortion 13 dBm 17 dBm 48 42 45 40 dBc Isolation Output to output Output to input 130 140 140 145 dB Phase noise 1 Hz 10 Hz 1 kHz 10 kHz 155 165 170 171 150 160 168 170 dBc Hz Temp delay Coefficient 0 50 ºC 1 2 1 5 ps ºC Allan Deviation Averaging Time in s 1 10 100 1000 10000 4 0 E ...
Страница 14: ...10 MHz 0 0 2 0 5 dB Impedance Input Output 50 50 Ohms Return loss Input S11 10 MHz Output S22 10 MHz 35 35 30 30 dB Distortion 13 dBm 17 dBm 45 42 40 40 dBc Isolation Output to output Output to input 130 140 140 145 dB Phase noise 1 Hz 10 Hz 1 kHz 10 kHz 150 160 169 169 147 157 167 167 dBc Hz Temp delay Coefficient 0 50 ºC 1 2 1 5 ps ºC Allan Deviation Averaging Time in s 1 10 100 1000 10000 4 0 E...
Страница 15: ...mount chassis 1U H 19 W 14 D Weight 4 5 kg 10 lbs AC Input Voltage Range 90 264 VAC 22 W 47 63 Hz DC Input Voltage Range 12 36 VDC 13 W Storage temperature 10 to 75 ºC Operation environment 0 to 50 ºC Humidity 5 to 95 Non condensing ...
Страница 16: ...lity for direct indirect or consequential damages or delay Any improper use operation beyond capacity substitution of parts not approved by SDI or any alteration or repair by others in such manner as in SDI s reasonable judgement affects the product materially and adversely shall void this warranty No employee or representative of SDI is authorized to change this warranty in any way or grant any o...
Страница 17: ... use within certain voltage limits 2014 30 EU The Electromagnetic Compatibility Directive and its amending directives 2011 65 EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Standards EN 55011 2009 A1 2010 Product family standard for Industrial Scientific and Medical ISM equipment E...