background image

INSTALLATION INSTRUCTIONS IP100SGK-EM

ELECTRIC LATCH RETRACTION DEVICE KIT

SARGENT MODELS: 8600, 8700 & 8800

P:\INSTALLATION INST\SWITCH KIT\INST-IP100SGK-EM.vsd     REV A    06-15    Page 1  

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email [email protected] 

801 Avenida Acaso, Camarillo, Ca. 93012  •   (805) 494-0622  •
www.sdcsecurity.com  •  E-mail: [email protected]

Remove the Head Assembly from the 
device.  Carefully run the Cable inside 
the rail over the hinge brackets.  
Attach the Bell Crank as shown.  Re-
install the Head Assembly to the 
device.  Remove access cover and 
attach the ELR assembly to the 
device with the supplied screw. 

Depress Latch 

Retractor and 
insert the Bell 

Crank as 

shown.

BELL 

CRANK

Latch 

Retractor

Run the cable through the ELR Clevis Block and 
Cable Sleeve.  Install the device to the door.  Mount 
the ELR assembly in the device by positioning the 
assembly close to the edge of the rail.  Use the 
mounting tab from the exit device to secure the ELR to 
the base.  Once the assembly is secure then use a    
7/64 drill bit to drill out the inserts and use the supplied 
screws to fasten kit to the device and door.

Attach the ELR to the device 
with the supplied screws.

CABLE 
SLEEVE

CLEVIS 
BLOCK

Carefully run the Cable inside the rail 
over the hinge brackets.

Energize

the ELR assembly, then pull the cable so that 

it retracts the latch far enough to clear the strike.  Hold 
the cable in position and secure the set screw firmly on 
the clevis block, so that the Cable Sleeve  secures the 
cable in block.  Test operation and re-attach access 
cover (NOTE: Access Cover can 

NOT

go back on the 

same way as it came off.  It must be rotated 180 
degrees).

ELECTRICAL DATA

12VDC @ 700/200mA

RED (+) BLK (-)

PATENT #8,851,530