SDC EntryCheck 920P Скачать руководство пользователя страница 1

The 

EntryCheck

™  920P Indoor/Outdoor Keypad is a surface-mount 

digital keyless entry system designed for access control applications.  
The backlit keys  are bright and easy-to-read. A heavy cast vandal 
resistant housing design with mounting plate allows the 920P  to be 
mounted on a  rugged surface or on a standard single-gang electrical 
box.  
  
The 920P has a capacity of 500 users. Users can be assigned to use 4 
to 6 digit  PIN codes and/or HID 125kHz proximity access credentials. An 
authenticated access can be programmed to activate one or both of the 
relay outputs. 

The timed “anti-passback” feature prevents using the same credentials  
twice  before a programmed waiting period has  elapsed.

Two long lasting solid state LED indicators show the status of the 
system.  The left bi-color indicator lights red to indicate power, then 
green when a relay is active (access grant, etc.).  The right indicator 
flashes yellow to indicate that the keypad is in programming mode.

An internal sounder can be programmed to beep each time a key is 
pressed or when an output is activated.  An internal jumper sets the 
sounder volume high or low.

The 

SENSE 

input can be configured one of two ways through 

programming .  When configured for “Door Sense”, the input is wired to a 
normally closed door position switch to detect when the door is opened 
or closed.  Forced entry or door ajar situations can then be detected. The 
“Auto-relock” feature can also be used to turn off the Main Relay output 
immediately when the door is closed after access has been granted to 
prevent “tailgating”.
When the 

SENSE 

input is configured for “Inhibit”, the input can be wired 

to a normally open “service” switch or automatic timer that will disable 
access while the switch is closed.

The 

REQUEST-TO-EXIT 

input can be wired to a normally open 

pushbutton to provide codeless activation of the Main Relay, Auxiliary 
Relay, Output #3 or Output #4 (programmable).

The 

ALARM SHUNT 

signal is available when access is granted.  This 

signal can be programmed to activate any of the relays or solid state 
outputs  to shunt alarm contacts on the access door/gate  preventing the  
triggering of an alarm when an authorized access occurs.

The 920P 

EntryCheck

™ is powered from a 12 or 24V AC or DC source. 

The non-volatile EEPROM memory retains  entry codes and 
programming when power is removed.  An internal jumper is provided to 
reset the master code.  The Main Relay has a 5 Amp capacity.  The 
Auxiliary Relay has a 2 Amp capacity.  Two solid state outputs, capable 
of sinking 100 mA to common are programmable for alarm shunting, or 
to signal forced entry, door ajar, keypad lockout, and keypad active 
conditions.

P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-920P       Rev K       08-21       Page 1

920P

EntryCheck 

TM

SPECIFICATIONS

Mechanical

Dimensions:  3.00" W x 5.75" H x 1.375" D

      (1.4375” wall projection)

Electrical

Input Voltage: 12/24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max

  Output Ratings

   Main Relay: Form “C” 5 Amps @ 28 Volts max

     Auxiliary Relay: Form “C” 2 Amp @ 28 Volts max

Type:  Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum

Environmental

Temperature: -4°F to 140°F (-20°C to 60°C)
Humidity: 5% to 95% non-condensing

Features

Security Door Controls

 

4 to 6 digit user codes

 

4 independent outputs

 

4 independent timers

 

2 Form C relay contacts

 

2 solid state open collector outputs

 

Program entry codes to activate one or 
two relays

 

Disable input

 

Door sense input

 

Request-to-exit/Reception input

 

Keypad tamper lockout

 

Timed anti-passback

 

Anti-tailgate

 

Two LED status indicators

 

Tactile key feel

 

Audible code entry verification

 

12V or 24V, AC or DC operation

                                                                

 

Keypad programmable

 

500 user codes

 

3 User Modes 

PIN or Card
Card Only
Card and PIN

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email [email protected] 

SECURITY DOOR CONTROLS   ■   WWW.SDCSECURITY.COM

[t] 800.413.8783  ■  805.494.0622  ■  E-mail: [email protected]  ■  801 Avenida Acaso, Camarillo, CA  93012  ■  PO Box 3670, Camarillo, CA  93011

INSTALLATION INSTRUCTIONS

Содержание EntryCheck 920P

Страница 1: ...RM SHUNT signal is available when access is granted This signal can be programmed to activate any of the relays or solid state outputs to shunt alarm contacts on the access door gate preventing the triggering of an alarm when an authorized access occurs The 920P EntryCheck is powered from a 12 or 24V AC or DC source The non volatile EEPROM memory retains entry codes and programming when power is r...

Страница 2: ...E7 E6 E5 E4 E3 E2 C NO C NC NO AUXILIARY OUTPUTS 100mA MAX TO COMMON NOT USED CAUTION IF THE UNIT IS AC POWERED MAKE SURE THAT THE SECONDARY OF THE SYSTEM IS ISOLATED FROM EARTH GROUND SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 QuickStart Programming Examples You must firs...

Страница 3: ...re to a good earth grounding point Suggested wiring size is 18 AWG for earth ground Sense Input RE Note The SENSE input gray wire can be programmed as either a door sense or inhibit input default inhibit Both features cannot be used at the same time Door Sense Detect forced entry or door ajar conditions Install a normally closed door switch on the door and route two wires from the switch to the ke...

Страница 4: ...d to be entered when programming a new code The 920 will internally add any zeros to fill digits determined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Output Toggle Mode When an output is programmed for Toggle Mode the output alternates from OFF to ON or from ON to OFF each time it is accessed When an output is toggled...

Страница 5: ... is 60 seconds Press 13 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Lockout Disable Select Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door This output may be timed or toggled Press 15 Output Output Output to Activate 0 4 1 ...

Страница 6: ...lay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length of time Output 4 activates when triggered Press 24 Seconds Seconds Output time in seconds 1 60 99 Toggle Mode Beep Sounds on Keystrokes Default Yes Selects whether or not the keypad beeps as each key is pressed P...

Страница 7: ...ST INSTRUCTIONS ACCESS CONTROLS INST 920P Rev K 08 21 Page 7 SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 Rubber Gasket Metal Bracket Keypad 1 Secure metal bracket to box or wall 2 Secure keypad to metal bracket using supplied security screw ...

Страница 8: ...8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 User Employee First Name Employee Last Name 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 ...

Отзывы: