SDC EntryCheck 920 Скачать руководство пользователя страница 1

The 

EntryCheck

™  920 Indoor/Outdoor Keypad is a surface-mount digital 

keyless entry system designed for access control applications.  The backlit 
keys  are bright and easy-to-read. A heavy cast vandal resistant housing 
design with mounting plate allows the 920  to be mounted on a  rugged 
surface or on a standard single-gang electrical box.  
  
The 920 has a capacity of 500 users. Users can be assigned to use 4 to 6 
digit PIN codes. An authenticated access  can be programmed to activate 
one or both of the onboard relay outputs. 

The timed “anti-passback” feature prevents using the same credentials  
twice  before a programmed waiting period has  elapsed.

Two long lasting solid state LED indicators show the status of the system.  
The left bi-color indicator lights red to indicate power, then solid green when 
a relay is active (access grant, etc.).  The right indicator flashes yellow to 
indicate that the keypad is in programming mode.

An internal sounder can be programmed to beep each time a key is 
pressed or when an output is activated.  An internal jumper sets the 
sounder volume high or low.

The 

SENSE 

input can be configured  two ways through programming .  

When configured for “Door Sense”, the input is wired to a normally closed 
door position switch to detect when the door is opened or closed.  Forced 
entry or door ajar situations can then be detected. The “Auto-relock” feature 
can also be used  to  turn off the Main Relay output immediately when the 
door is closed after access has been granted to prevent “tailgating”.
When the 

SENSE 

input is configured for “Inhibit”, the input can be wired to 

a normally open “service” switch or automatic timer that will disable access 
while the switch is closed.

The 

REQUEST-TO-EXIT 

input can be wired to a normally open pushbutton 

to provide codeless activation of the Main Relay, Auxiliary Relay, Output #3 
or Output #4 (user programmable).

The 

ALARM SHUNT 

signal is available when access is granted.  This 

signal can be programmed to activate any of the relays or solid state 
outputs  to shunt alarm contacts on the access door/gate  preventing the  
triggering of an alarm when an authorized access occurs.

The 920 

EntryCheck

™ is powered from a 12 or 24V AC or DC source. The 

non-volatile EEPROM memory retains  entry codes and programming when 
power is removed.  An internal jumper is provided to reset the master code.  
The Main Relay has a 5 Amp capacity.  The Auxiliary Relay has a 2 Amp 
capacity.  Two solid state outputs, capable of sinking 100 mA to common 
are programmable for alarm shunting, or to signal forced entry, door ajar, 
keypad lockout, request-to-exit, and keypad active conditions.

P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-920       Rev G       04-21       Page 1

920

 

EntryCheck 

TM

SPECIFICATIONS

Mechanical

Dimensions:   3.00" W x 5.75" H x 1.375" D

      (1.4375” wall projection)

Electrical

Input Voltage: 12/24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max

Output Ratings

   Main Relay: Form “C” 5 Amps @ 28 Volts max

     Auxiliary Relay: Form “C” 2 Amp @ 28 Volts max

Type:  Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum

Environmental

Temperature: -4°F to 140°F (-20°C to 60°C)
Humidity: 5% to 95% non-condensing

FEATURES

                                                                

 

Keypad programmable

 

500 user codes

 

4 to 6 digit user codes

 

4 independent outputs

 

4 independent timers

 

2 Form C relay contacts

 

2 solid state open collector outputs

 

Program entry codes to activate one or 
two relays

 

Disable input

 

Door sense input

 

Request-to-exit/Reception input

 

Keypad tamper lockout

 

Timed anti-passback

 

Anti-tailgate

 

Two LED status indicators

 

Tactile key feel

 

Audible code entry verification

 

12V or 24V, AC or DC operation

Security Door 

Controls

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email [email protected] 

SECURITY DOOR CONTROLS   ■   WWW.SDCSECURITY.COM

[t] 800.413.8783  ■  805.494.0622  ■  E-mail: [email protected]  ■  801 Avenida Acaso, Camarillo, CA  93012  ■  PO Box 3670, Camarillo, CA  93011

INSTALLATION INSTRUCTIONS

Содержание EntryCheck 920

Страница 1: ...SHUNT signal is available when access is granted This signal can be programmed to activate any of the relays or solid state outputs to shunt alarm contacts on the access door gate preventing the trig...

Страница 2: ...N O GROUND OUTPUT 4 OUTPUT 3 GROUND SENSE REQUEST TO EXIT GROUND E1 E8 E7 E6 E5 E4 E3 E2 C NO C NC NO AUXILIARY OUTPUTS 100mA MAX TO COMMON NOT USED KEYPAD POWER WIRE HARNESS E1 E8 MAIN RELAY AUXILIA...

Страница 3: ...ALARM PANEL NO ZONE COMMON LOW VOLTAGE LAMP BLACK BLACK OUTPUT 4 EACH OUTPUT 100 mA MAXIMUM Wire Pigtail Wire Pigtail Fig 4 Basic Door Installation Wiring TO POWER SUPPLY KEYPAD POWER 12 or 24 VOLTS A...

Страница 4: ...n again Note Leading zeros zeros before the code number e g 0241 do not need to be entered when programming a new code The 920 will internally add any zeros to fill digits determined by the entry code...

Страница 5: ...Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Select Keypad Lockout Output Default No Output Sets which output activates when the keypad is locked out after too many i...

Страница 6: ...ay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length of time Outpu...

Страница 7: ...With supplied screws and hole expansion anchors SURFACE MOUNT P INST INSTRUCTIONS ACCESS CONTROLS INST 920 Rev G 04 21 Page 7 SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E...

Страница 8: ...les POST MOUNT WITH SHROUD 4 4 P INST INSTRUCTIONS ACCESS CONTROLS INST 920 Rev G 04 21 Page 8 SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801...

Отзывы: