41
test reports
teSt reSUltS
teStinG laBoratory
manUfactUrer
moDel
iSSUe Date
inVeStiGatinG officer
reSUltS
conclUSion
Hrl technology
Seguin Duteriez
Visio 8 plus
09.12.2015
Steve marland
testing of the maximum power(kW) output of the Visio 8 insert solid fuel
appliance was performed at the high burn rate prescribed in aSnZS4013
(2014) on the 24th of november 2015. the appliance produced a
maximum Heat output of 27.8kW
exemption from testing the Visio 8 insert solid fuel appliance should be
claimed under section 1.2.3 (b) of aS/nZS4013 (2014) as the maximum
heat output from combustion is greater than 25kW when fired at the
prescribed high burn rate and that the appliance is intended for space
heating by means of transferring heat to the living are by ducted hot air.
Visio 8 applianCe power output test
teStinG laBoratory
manUfactUrer
moDel
iSSUe Date
inVeStiGatinG office
reSUltS
conclUSion
Hrl technology
Seguin Duteriez
Super 9
09.12.2015
Steve marland
testing of the maximum power(kW) output of the Visio 8 insert solid fuel
appliance was performed at the high burn rate prescribed in aSnZS4013
(2014) on the 24th of november 2015. the appliance produced a
maximum Heat output of 26kW
exemption from testing the Visio 8 insert solid fuel appliance should be
claimed under section 1.2.3 (b) of aS/nZS4013 (2014) as the maximum
heat output from combustion is greater than 25kW when fired at the
prescribed high burn rate and that the appliance is intended for space
heating by means of transferring heat to the living are by ducted hot air.
super 9 applianCe power output test