eXiStinG BricK cHimney inStallation
option 1: install unit free standing
recommended 100mm clearance on the sides and back of the
firebox
option 2: inbuilt with Vents on the bottom
and top of the fireboX
custom made vent facade can be made with a minimum metal
vent size of 100mm x 600mm on the top of the firebox and
another 100mm x 600mm metal vent on the bottom of the
firebox. Please note that the firebox must be elevated using
masonry material so that a sufficient amount of air flows
underneath the appliance.
option 3: inbuilt with Vents on the sides of
the CaVity*
Ventilation options
a minimum of two air intake grills are required at the bottom
and a minimum of two air out take grills are required on top of
the masonry enclosure. all vents can be positioned either side
or the front of the masonry enclosure.
Minimum vents sizes are 100mm x 300mm with a minimum
quantity of four*
.
*the vent sizes and quantity can be adapted and changed
but they must meet the minimum ventilation requirements
as specified above. For custom made vents please contact
your nearest dealer. all Vents must not be plastiC or
Combustible.
*all air vents must have a minimum clearance to combustibles
of 600mm in front and 300mm above the metal vent itself.
Ventilation is required on the enclosure to help with air circulation.