6 Commands
6.62
MYcall
Default setting: ROM-Callsign
Parameter: CALL Station's
callsign, 2 to 8 characters.
Defines the own Callsign. Whenever the callsign is received during STBY, the PTC
performs slave synchronization and responds with a control signal attempting to establish
the requested connect. With an active AMTOR prompt
MYcall
sets one ´s own Selcall.
Although there is a convention how to create a Selcall out of a callsign this procedure
isn´t always reasonable. Basicly an AMTOR selcall consits of 4 letters. From a normal
call usually the first and the last 3 letters are used to assemble the selcall e.g. DK5FH
→
DKFH, DL3FCJ
→
DFCJ. If the call only contains 3 letters, the first one is used twice.
Mycall
without argument returns the call or selcall as currently set.
After power-on the firmware checks if there is a valid setting for the PACTOR-MYCALL
available. If it is the case (that means that the setting is different to *SCSPTC*) it copies
the PACTOR-MYCALL into all PACKET-channels which still contain SCSPTC and
replaces it by the valid MYCALL. The same procedure is performed if the
MYcall
command is executed with a valid call as argument in the
cmd:-
menu. This ensures that
after a
RESTart
or after the first power-on all calls are set to a valid value.
6.63
MYLevel
Default setting: 3
Parameter: 1 The PTC-IIex behaves as a Level I controller.
2 The PTC-IIex behaves as a Level II controller, and will
switch to PACTOR-II when the other station is so fitted.
3 The PTC-IIex behaves as a Level III controller, and will
switch to PACTOR-III when the other station is so fitted.
This command serves to maintain the highest possible PACTOR level. The parameter
should only be set to 1 or 2 for test purposes. The default value 3 leads to a very reliable
and automatic level choice procedure during the link initialization, so that the link always
proceeds using the highest possible level. There are no disadvantages incurred by using
this
auto negotiate
procedure.
MYLevel
without argument leads to a 2 line output. The first line displays the maximum
possible link level ( 1…3, as set with
MYLevel
). The second line displays the link level
of the current or last link. This may be useful if PC software wants to test in which link
level PACTOR links runs or ran.
6.64
MYSelc
Default setting: ROM-Selcall
Parameter: ADDR Own selcall of the PTC.
63
Содержание PTC-IIex
Страница 14: ...List of Figures and Tables XII...
Страница 30: ...3 Installation 16...
Страница 108: ...7 Audio 94...
Страница 126: ...8 FAX 112...
Страница 173: ...12 SYStest 159...
Страница 183: ...14 Circuit Description 169...
Страница 195: ...15 Basics 181...
Страница 201: ...B Technical Data 187...
Страница 202: ...C Layout Appendix C 19 Layout B 1 Motherboard Figure B 1 Motherboard 188...
Страница 203: ...C Layout 189...
Страница 215: ...Index 202...