9 Packet-Radio
Parameter: CALL Alternative station callsign.
MYAlias
is handled as
MYcall
for incoming connects, and can also be used as an
alternative station callsign.
The default of the
MYAlias
callsign is the PACTOR MYCALL entered first of all., but
gets the SSID 15. If for example the global MYCALL on the PACTOR is set to
DL6MAA, the PTC-IIex sets the MYAlias to DL6MAA-15.
This default setting can be changed at any time using the
MYAlias
command of the
pac:-
menu.
9.6.24
MYcall
Default setting: SCSPTC
Parameter: CALL
Callsign of the PTC.
Callsign for the Packet mode.
For each channel an own callsign can be defined temporarily. After a disconnect the
callsign will always be taken from channel 0 again.
After switching on the PTC-IIex the firmware checks if a valid callsign is written in the
PACTOR-MYCALL. In this case (i.e. no *SCSPTC* defined as PACTOR-MYCALL),
the PTC-IIex copies the PACTOR-MYCALL to all PR channels which are still having
SCSPTC as MYCALL, and overwrite the SCSPTC with the valid mycall. If the
MYcall
command is executed on the PACTOR side with a valid callsign as an argument, the
PTC-IIex also checks all PR channels for SCSPTC, and if necessary the new defined
PACTOR-MYCALL is taken over to the PR channels replacing the SCSPTC setting.
9.6.25
MYMail
Default setting: MYCALL-8
Parameter: CALL Callsign of the PR mailbox.
Identical to the
MYcall
command in the
pac:-
menu, however sets the
Mycall
of the
PTC-IIex PR-mailbox (BBS-MYCALL).
The BBS callsign is set automatically to MYCALL-8, either at the first start (when the
Flash-Call
in the BIOS has been defined), or when ones own PACTOR-MYCALL has
been set. If, for example, DL1ZAM is given as the first PACTOR-MYCALL then the PR-
mailbox can be connected to under the callsign DL1ZAM-8.
9.6.26
PACLen
Default setting: 255
Parameter: X
1… 255, transmit packet length
Sets the maximum PR transmit packet length, when the PTC is in Terminal mode. (In
hostmode is the
PAClen
value not used, as the Hostmode program itself defines the
packet length). Packet lengths smaller than 255 are only useful if the link to the distant
station has a lot of errors.
126
Содержание PTC-IIex
Страница 14: ...List of Figures and Tables XII...
Страница 30: ...3 Installation 16...
Страница 108: ...7 Audio 94...
Страница 126: ...8 FAX 112...
Страница 173: ...12 SYStest 159...
Страница 183: ...14 Circuit Description 169...
Страница 195: ...15 Basics 181...
Страница 201: ...B Technical Data 187...
Страница 202: ...C Layout Appendix C 19 Layout B 1 Motherboard Figure B 1 Motherboard 188...
Страница 203: ...C Layout 189...
Страница 215: ...Index 202...