9 Packet-Radio
9.6.5
CMsg
Default setting: 1
Parameter: 0
Switch connect text off.
1
Switch connect text on.
2
Switch connect text on and evaluation of special functions.
Enable or disable the connect text.
If
CMsg
is set to 2, the following sequences
//B
<CR> and
//Q
<CR> are accepted
additionally. The two sequences are noticed if they occur at the beginning of a line and
are closed directly with <CR> or <Return>.
//B
initiates the sysop-bell (duration about
14 seconds). After receiving
//Q
the PTC initiates a disconnect.
The sysop-bell is set using the
BEll
command of the
cmd:-
menu. To disable this
function (refer to chapter
6.11
, page
42
)
9.6.6
Connect
Default setting: none
Parameter:
<target-call> [<Digi1> <Digi2>.....]
Connect
sets up the AX.25 link.
Connect to DL1ZAM:
pac:
C
DL1ZAM
<Return>
If the link takes place via one or more digipeaters, then the list of digipeaters should be
given directly after the target callsign.
Connect DL6MAA via DB0KFB
pac:
C
DL6MAA DB0KFB <
Return
>
9.6.7
CONStamp
Default setting: OFF
Parameter: OFF Time
stamp
off.
ON
Time
stamp
on.
Activates the display of time stamps on connect and disconnect messages.
9.6.8
CONVerse
Manually activates the converse mode. This function is seldom needed, as the PTC-IIex
automatically switches to the converse mode after a successful link up.
Alternatively a
K
may be used, as abbreviation for
CONVerse
.
9.6.9
CStatus
CStatus
lists the condition of the channel, the link status.
121
Содержание PTC-IIex
Страница 14: ...List of Figures and Tables XII...
Страница 30: ...3 Installation 16...
Страница 108: ...7 Audio 94...
Страница 126: ...8 FAX 112...
Страница 173: ...12 SYStest 159...
Страница 183: ...14 Circuit Description 169...
Страница 195: ...15 Basics 181...
Страница 201: ...B Technical Data 187...
Страница 202: ...C Layout Appendix C 19 Layout B 1 Motherboard Figure B 1 Motherboard 188...
Страница 203: ...C Layout 189...
Страница 215: ...Index 202...