SCS CTC034-030-3-WW Скачать руководство пользователя страница 1

TB-9037

 Page 1 of 10

© 2016 DESCO INDUSTRIES, INC.

Employee Owned

SCS 

- 926 JR Industrial Drive, Sanford, NC 27332

East: (919) 718-0000 | West: (909) 627-9634 • Website: 

StaticControl.com

EM Aware Monitor

Installation, Operation and Maintenance

December 2016

Description

The SCS EM Aware Monitor monitors up to three key 

parameters that keep you aware of critical symptoms 

of ESD problems: ESD events, change in static voltage 

field, and ionizer performance*.  The thresholds for 

these parameters are fully adjustable.  The monitor is 

constructed of an aluminum enclosure, LCD display, 

control joystick, remote antenna, power adapter and 

data output terminal.
ESD events generate electromagnetic radiation.  

The stronger the ESD event, the stronger the 

electromagnetic radiation.  The EM Aware Monitor is a 

miniature radio receiver tuned to detect and measure 

the unique waveform generated by an ESD event.
The EM Aware Monitor and its accessories are available 

as the following item numbers:

Item

Description

CTC034-030-3-WW

EM Aware Monitor, ESD Events, 

4.20mA Output

CTC034-030-5-WW

EM Aware Monitor, ESD Events, 

Modbus Output

CTC034-031-5-WW

EM Aware Monitor, ESD Events, 

Static Field & Ionization, Modbus 

Output

770038

Data Logger, Dataq DI-710, for EM 

Aware Monitor

CTA212

Power Adapter, 100-240VAC Input, 

12VDC 1.5A Output, All Plugs

CTC111-6FT

Antenna, Room Temperature, 6 ft.

CTC118-6FT

Antenna, High Temperature, 6 ft.

CTC118-10FT

Antenna, High Temperature, 10 ft.

Made in the

United States of America

Figure 1.  SCS EM Aware Monitor

 USER GUIDE TB-9037

Packaging

1  EM Aware Monitor

CTC111-6FT

 Antenna with 6 ft. Cable

1  Monitor Ground Cord (Green and Yellow)

1  Power Adapter, 12VDC, with interchangeable plugs

  (North America, UK/Asia, Europe)

1  Certificate of Calibration

Features and Components

*Ionization monitoring is only available in item CTC034-031-5-WW.  

Compatible with critical environment ionizers only.  The ionizer must 

have a balance (offset voltage) of ±5V or better.

A. Antenna Input:

 Connect to the antenna using the 

included cable. 

B. LCD Display:

 Displays measurements and settings.

C. Joystick:

 Toggles displayed measurements and 

monitor settings.

D. Power Jack:

 Connect the included 12VDC power 

adapter here.

E.  Ground Terminal:

 Common ground point for the 

monitor.

F.  Data Output:

 Model 

CTC034-030-3-WW

 outputs 

a 4.20 mA analog signal for use with the 

770038

 Data 

Logger.
Models 

CTC034-030-5-WW

 and 

CTC034-031-5-WW

 

output Modbus serial communication for use with 

Static 

Management Program (SMP)

.

Figure 2.  EM Aware Monitor features and components

F

E

A

B

C

D

Содержание CTC034-030-3-WW

Страница 1: ...onization Modbus Output 770038 Data Logger Dataq DI 710 for EM Aware Monitor CTA212 Power Adapter 100 240VAC Input 12VDC 1 5A Output All Plugs CTC111 6FT Antenna Room Temperature 6 ft CTC118 6FT Anten...

Страница 2: ...rformance position the antenna as close as practically possible to the anticipated source of ESD activity Use the mounting tabs on the antenna to properly secure it to the desired location 3 Connect t...

Страница 3: ...dicator will appear on the top left corner of the display to indicate that the ESD threshold value can be modified Toggle the joystick left to decrease the threshold Toggle the joystick right to incre...

Страница 4: ...e top left corner while the settings are saved The monitor will then re boot after the save is completed NOTE The monitor will revert back to its last saved settings if idled for 10 seconds while in t...

Страница 5: ...ed every three minutes Static voltage monitoring becomes idle when balance and decay tests are performed ESD event monitoring operates normally 3 To change the voltage range and thresholds push down a...

Страница 6: ...ed Smart Coefficient SCF The Smart Coefficient SCF feature works in conjunction with the static voltage field channel This feature is useful when an approximate voltage is desired especially when the...

Страница 7: ...e CTC034 030 3 WW EM Aware Monitor to build a diagnostic kit and help identify problematic ESD areas DATAQ WinDaq Data Acquisition Software is included with every unit and it displays and stores real...

Страница 8: ...nter Positive Output Plug 5 5 mm O D x 2 1 mm I D x 9 5 mm L ESD Event Monitor Measurement Magnitude ESD Event ESD Event Threshold Default setting 80 dB V Raw Input Signal 60 dB V 1mV to 134 dB V 5 0V...

Страница 9: ...power supply is difficult Always locate the power source socket or outlet near the equipment The power supply plug serves as the disconnect device Caution To reduce the risks associated with environme...

Страница 10: ...ead mercury hexavalent chromium polybrominated biphenyls or polybrominated diphenyl ethers or b 0 01 by weight for cadmium Unless otherwise stated by SCS in writing this information represents SCS bes...

Отзывы: