Ice Making Section
Major Components:
TXV
-
Water Pump
-
Water Level Sensor
- signals water level to the
controller
Controller
- operates both the ice machine section
and the compressor unit.
Drain Valve
- opens to allow pump to drain
reservoir
Water Inlet Valve
- 1.25 GPM solenoid valve that
opens to fill the reservoir
Liquid, Vapor and Suction Connections
- where
the pre-charged tubing kits connect to.
Drain Tube
- internal vent eliminates need for
external vent
Prodigy Eclipse
ä
600, 800, 1000
February 2008
Page 14
Component Location, Back View