Installation andUser's Manual forFlake and Nugget Ice Machine
Models FME504, FME804, NME454,NME654
Страница 1: ...Installation and User s Manual for Flake and Nugget Ice Machine Models FME504 FME804 NME454 NME654...
Страница 2: ...NTENANCE Page 11 AIR COOLED MAINTENANCE Page 12 BEARING MAINTENANCE Page 13 AUGER MAINTENANCE Page 14 REMOVAL AND REPLACEMENT Bin Controls Page 15 What to Do Before Calling for Service Page 16 Note th...
Страница 3: ...s designed to be installed indoors in a controlled environment Min Max Air Temperature 500 F 1000 F Water Temperature 400 F 1000 F Water Pressure 20 PSI 80 PSI Voltage for 115v model 104 126 Compared...
Страница 4: ...ge 3 Bin Top Kit Required SAMPLE BIN AND MACHINE COMBINATIONS FME804 ON BH550 NME654 ON BH801 FME804 ON BH900 The Nameplate is located on the back of the machine A Serial Number Plate is located insid...
Страница 5: ...the 2 service panels that will face each other 3 Add a strip of gasket such as Scotsman part number 19 0503 04 to the 2 base edges that will face each other and around service panel space on the 2 pa...
Страница 6: ...E504 804 January 2007 Page 5 FOR THE INSTALLER Location TWO UNITS ON ONE BIN ALLOW ROOM FOR AIR CIRCULATION AND SERVICE ACCESS ALLOW AIR SPACE ON BOTH SIDES Airflow Notice Air flow is in the sides and...
Страница 7: ...to all lines must always be above 20 PSIG and below 80 PSIG Drains Air Cooled Models Connect a drain tube to the FPT drain at the back of the cabinet the drain line is of the gravity type and inch pe...
Страница 8: ...ME504 804 January 2007 Page 7 WATER COOLED AIR COOLED POWER SUPPLY FOR THE INSTALLER Final Check List 1 Is the ice system installed indoors in a location where the air and water temperatures are contr...
Страница 9: ...e checked it should be 34 PSIG or 4 PSIG The suction line temperature at the compressor is normally very cold nearly to the point of frost up to the compressor body but not on it The air cooled discha...
Страница 10: ...water reservoir until it is full Wait 15 minutes then switch the master switch to ON 9 As the ice maker begins to use water from the reservoir continue to add more cleaning solution to maintain a ful...
Страница 11: ...ean as illustrated 2 The ice machine senses water level by a probe located in the water reservoir At least twice a year the probe should be removed from the reservoir and the tip wiped clean of minera...
Страница 12: ...move the filter The filter may be cleaned or replaced B Clean the condenser the condenser may appear to be clean on the surface but it can still be clogged internally Check with a flash light from the...
Страница 13: ...should rotate smoothly To remove the breaker remove the lower ice chute then take out all four allen head cap screws and pull the breaker off the auger and evaporator If the bearing only needs grease...
Страница 14: ...arding water treatment For more information on removal of these parts see REMOVAL AND REPLACEMENT 1 To remove the auger remove the front and top panels 2 Push bail clamp back from the top of the chute...
Страница 15: ...hrough the holes in the ice chute NME454 654 FME504 804 January 2007 Page 14 ICE CHUTE SLIDE BIN CONTROLS LEFT AND RIGHT REMOVAL AND REPLACEMENT Bin Controls RESERVOIR 1 Shut off water supply 2 Remove...
Страница 16: ...SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills IL 60061 800 533 6006 www scotsman ice com 17 3154 01...