6. Lift up the entire spray platen, disconnect water hose and take it out to clean the water jets
separately
7. Using a container, poor water into the bottom of the sump/freezing chamber to rinse out most of
of any loose scale deposit.
8. Install again the spray platen, the curtain as well as the bottom plastic cup.
Cleaning the Water System:
9. Prepare the cleaning (descaling) solution by diluting into a container, warm water (hand hot !!)
with a quantity of Ice Machine Cleaner based on 10% dilution rate (ie
–
5 litres of water, 500ml
descaling acid).
WARNING. The Ice Machine Cleaner/Sanitiser contains harmful fluids.
Please refer to any supplied MSDS document issued for handling of fluids.
KEEP OUT OF THE REACH OF CHILDREN.
10. Remove the plastic evaporator cover; slowly pour over the evaporator platen the cleaning
solution. With the help of a brush, dissolve the most resistant and remote scale deposits on the
platen.
11. Switch ON again the machine at the front master button switch, place the rocker switch into
position number (II) to put the machine in cleaning mode.