REFRIGERATION SYSTEM: HP62 (R-404A) Refrigerant
THIS ICE MACHINE USES HP62 REFRIGERANT
AND POLYOLESTER COMPRESSOR OIL
DO NOT USE MINERAL OIL IN THIS
REFRIGERATION SYSTEM.
••
HP62 is a "Near Azeotrope", and therefore
liquid charging is required.
¤
Weigh in as much of the charge (as liquid) as
possible into the discharge size.
¤
Install a sight glass between the suction side
and the gage manifold. Use the manifold
valve to "flash off" the liquid refrigerant before
it enters the ice machine. Do this until the
proper charge is weighed into the system.
••
When the system is serviced, a special liquid
line dryer is required (see parts list).
••
Polyolester oil absorbs water very easily, and
therefore when the system is opened for
service, it must be re-sealed as soon as
possible (15 minutes maximum).
••
Special leak detection equipment is required to
locate small refrigerant leaks. Usually a leak
detector capable of detecting a Halogenated
refrigerant or HFC-134a will work. Check with
the leak detector manufacturer if in doubt.
••
Do NOT mix with air for leak testing.
VAPOR VAPOR
TEMP. PRESSURE TEMP. PRESSURE
(DEG F) (PSIG) (DEG F) (PSIG)
-20 . . . . . . 17
70 . . . . . . . 146
-18 . . . . . . 18
72 . . . . . . . 150
-16 . . . . . . 20
74 . . . . . . . 155
-14 . . . . . . 21
76 . . . . . . . 161
-12 . . . . . . 23
78 . . . . . . . 166
-10 . . . . . . 24
80 . . . . . . . 171
-8 . . . . . . . 26
82 . . . . . . . 177
-6 . . . . . . . 28
84 . . . . . . . 182
-4 . . . . . . . 29
86 . . . . . . . 188
-2 . . . . . . . 31
88 . . . . . . . 194
0 . . . . . . . 33
90 . . . . . . . 200
2 . . . . . . . 35
92 . . . . . . . 206
4 . . . . . . . 37
94 . . . . . . . 212
6 . . . . . . . 39
96 . . . . . . . 219
8 . . . . . . . 41
98 . . . . . . . 225
10 . . . . . . . 43
100 . . . . . . 232
12 . . . . . . . 46
102 . . . . . . 239
14 . . . . . . . 48
104 . . . . . . 246
16 . . . . . . . 50
106 . . . . . . 253
18 . . . . . . . 53
108 . . . . . . 260
20 . . . . . . . 55
110 . . . . . . 268
22 . . . . . . . 58
112 . . . . . . 275
24 . . . . . . . 60
114 . . . . . . 283
26 . . . . . . . 63
116 . . . . . . 291
28 . . . . . . . 66
118 . . . . . . 299
30 . . . . . . . 69
120 . . . . . . 307
32 . . . . . . . 72
122 . . . . . . 316
34 . . . . . . . 75
124 . . . . . . 324
36 . . . . . . . 78
126 . . . . . . 333
38 . . . . . . . 81
128 . . . . . . 342
40 . . . . . . . 85
130 . . . . . . 351
42 . . . . . . . 88
132 . . . . . . 360
44 . . . . . . . 91
134 . . . . . . 370
46 . . . . . . . 95
136 . . . . . . 379
48 . . . . . . . 99
138 . . . . . . 389
50 . . . . . . . 102
140 . . . . . . 399
52 . . . . . . . 106
142 . . . . . . 409
54 . . . . . . . 110
144 . . . . . . 420
56 . . . . . . . 114
146 . . . . . . 430
58 . . . . . . . 118
148 . . . . . . 441
60 . . . . . . . 123
150 . . . . . . 452
62 . . . . . . . 127
152 . . . . . . 464
64 . . . . . . . 132
154 . . . . . . 475
66 . . . . . . . 136
156 . . . . . . 487
68 . . . . . . . 141
158 . . . . . . 499
Pressure-Temperature Chart for HP62
CME500
August 1994
Page 22