The location of the equipment should be selected
with care. Consideration should be given to allow
adequate space for air cooled models to breathe.
The ice machine is not designed for outdoor use. It
must be installed indoors, in a controlled environment.
The air and water temperatures must not exceed
rated limits.
Scotsman assumes no liability or responsibility of
any kind from products manufactured by Scotsman
that have been altered in any way, including the use
of any part and/or other components not specifically
approved by Scotsman.
Scotsman reserves the right to make design changes
and/or improvements at any time.
Specifications and design are subject to change
without notice.
Delivery:
Check for freight damage before proceeding
with the equipment installation. Be sure
to inspect the equipment carefully for any
damage that may not be evident on the
outside of the carton. Contact the freight
carrier immediately to report any damage and
file a claim.
Safety:
•
Do not operate equipment that has been
damaged.
•
Refer all maintenance to qualified personnel.
• Never operate the ice maker with any covers,
panels or other parts removed or not properly
secured.
• Instruct all personnel in the proper use of the
equipment.
• Clean up any spillage immediately.
Failure to comply with all installation guidelines may
cause personal injury, equipment or property damage
and may void the product warranty.
Note: Important Installation Advice
• Always install the ice maker on a stable and level
surface.
• Always secure the ice maker to the ice storage
means.
•
Do not install the equipment in wet areas.
•
Do not locate the equipment near any heat
source, in direct sunlight, in hot ambient areas, or
without proper clearance for ventilation. Placing
equipment in these locations will result in reduced
capacities, high system pressures and may cause
equipment failure.
Drains
Separate drains must be provided for the ice maker
and ice bin. The size of the drain tubing must never
be reduced along its length.
Make sure that the building drain system can
accommodate all the drain water from the ice machine
operation.
Individual drains must never be directly connected
to a common manifold, drain or standpipe. If
individual drains are to be discharged into a
common manifold, drain or standpipe, a minimum
38mm (1.5”) air gap must be provided at each
connection. This is to prevent any backflow or
back-siphonage of drain water into the ice maker or
ice bin.
Placement and Guidelines