Removal And Replacement
Ice Breaker and Auger Removal
Note: When the unit is installed under the counter,
there is not enough room to remove the auger
unless the evaporator is dismounted from the
gearmotor or the ice machine is pulled out from
under the counter.
1. Remove the hood, door and ice storage bin.
2. Remove stainless steel cover plate.
3. Remove cover from reservoir, and block the float
or shut off the water supply.
4. Locate evaporator drain and drain the
evaporator/reservoir.
5. Locate and remove two permagum plugs on
back of evaporator.
6. Remove two phillips screws from the back side
of the evaporator.
7. Obtain a 1 1/2" pipe thread tee.
8. Remove the sealing cap.
9. Install the Tee, it will screw onto the breaker,
which has 1 1/2" NPT threads.
10. Pull up on the Tee or insert a bar thru the Tee
and pull up on it to remove the auger and top
bearing retainer.
When the auger is free, the bolt holding it to the
bearing can be removed to allow the bearing
retainer to be separated from the auger.
Then the bearing can be serviced or the bearing
retainer (breaker) replaced.
AFE424
April 2010
Page 21
Sealing Cap
Top of Bearing Thrust Washer
Thrust Washer and Bearing
Thrust Bearing Surface