4.4 ELECTRICAL REQUIREMENTS
Ö
CAUTION: TO PREVENT DAMAGE TO THE MOTOR AND DANGER TO THE OPERATOR,
ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LICENSED ELECTRICIAN.
All machines are wired for three phase electrical power unless otherwise specified by customer. The sup-
ply voltage should be (+ or -) 10% of the motor voltage rating, to insure satisfactory machine perfor-
mance. Check the motor data tag for full load current requirements.
The electrical diagram for the machine is inside the cover of the control box. THE DIAGRAM IS ALSO
IN FIGURE 4. For electrical supply lines ten feet (3 m) or shorter, we recommend at least 12 and prefer-
ably 10, gauge wire. For longer supply lines, use at least 10 gauge and preferably, 8 gauge.
We do not recommend supply lines longer than twenty five feet (7.5 m).
POWER REQUIREMENTS:
Motor frame
3PH=182T
1PH=184T
MOTOR VOLTAGE
FULL LOAD CURRENT
(VAC)
(AMPS)
208
31
230
29.6
460
14.8
575
12
230 (single phase)
40
Motor power rating:
10hp Speed 1,725 RPM
KVA power rating:
7.9 KVA Frequency 60 HZ
Starting Current:
210% Full Load
PAGE 10
Содержание SHEARMASTER 610
Страница 1: ...You have downloaded a manual for our Model SHEARMASTER 610 Ironworker...
Страница 2: ...www scotchman com MODEL SHEARMASTER 610 24 PLATE SHEAR SEPTEMBER 2021...
Страница 12: ...PAGE 11 FIGURE 4...
Страница 14: ...PAGE 13 FIGURE 5...
Страница 24: ...PAGE 23 FIGURE 13...
Страница 34: ...PAGE 31 FIGURE 14...
Страница 38: ...PAGE 35 FIGURE 17...
Страница 40: ...PAGE 37 FIGURE 18...
Страница 42: ...FIGURE 19 PAGE 39 A H G I J K A B B L M O N P D C A B Q F E R...
Страница 46: ...PAGE 43 FIGURE 22...
Страница 48: ...PAGE 45 FIGURE 23...
Страница 50: ...PAGE 47 FIGURE 24...
Страница 51: ...PAGE 48 9 12 ELECTRICAL HYDRAULIC SCHEMATICS FIGURE 25...
Страница 52: ...PAGE 49 FIGURE 26...
Страница 53: ...PAGE 50 FIGURE 27...