Scolmore ESP beacon BA4ZM Скачать руководство пользователя страница 1

 

 

 

 

 

Assist Call BA4ZM   

Four Zone Controller 

 

 

 

 

 

 

 

Installation and Operation Manual

 

 

 

 

 

 

 

Содержание ESP beacon BA4ZM

Страница 1: ...Assist Call BA4ZM Four Zone Controller Installation and Operation Manual ...

Страница 2: ...y Information 4 4 1 Unpacking the BA4ZM 5 5 Installation 5 5 1 Connecting the BA4ZM Four Zone Controller 5 5 2 Schematic Example 6 5 3 Additional Functions 6 5 3 1 Buzzer Volume Control 6 5 3 2 Fault Monitored Zones 6 5 3 3 Volt Free Relay 6 5 3 4 Lamp Buzzer Test 7 5 4 System Operation 7 5 4 1 Raising the Alarm inside the WC 7 5 4 2 Indication outside the WC 7 5 4 3 Acknowledging the alarm 7 5 4 ...

Страница 3: ...ny order so wiring runs can be kept to a minimum The Assist Call system wired from a 4 zone controller features BS8300 acknowledge function this requires that visual and audible feedback should be provided to indicate that when the alarm has been operated the emergency assistance call has been acknowledged and is being actioned Note an indication that assistance is on its way will reassure those i...

Страница 4: ...in EN60950 Low Voltage Directive and must be EARTHED The BA4ZMPS requires a 3A switched fuse spur Do not connect 230vAC to the BA4ZMPS Controller Caution Indoor Use Only Warning Shock Hazard Isolate Before Opening Warning TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE Warning THIS UNIT MUST BE EARTHED Warning NO USER SERVICEABLE PARTS ...

Страница 5: ...acking and check the contents against the following list BA4ZM Four zone controller c w 6 no 2 way fitted connectors Instruction Sticker to be located near the controller Installation and operation manual Accessory pack with the following contents o 2no device mounting screws o 4 no EOL 10K resistors 5 Installation 5 1 Connecting the BA4ZM Four Zone Controller The BA4ZM controller mounts ono a 25m...

Страница 6: ...tage ELV Wiring Always segregate low voltage wiring from the main wiring 5 2 Schematic Example Note The plates can be wired in any order to suit the installation 5 3 Additional Functions 5 3 1 Buzzer Volume Control There is a potentiometer on the rear of the PCB labelled Sounder volume turning it anti clockwise reduces the volume 5 3 2 Fault Monitored Zones The line circuits are monitored for open...

Страница 7: ...flashing to steady and the internal sounder will sound intermittently every 15 seconds The ceiling pull cord indication will extinguish the blue indicator on the cancel plate and the over door indicator changes state from flashing to steady with intermittent sounder operation every 15 seconds to confirm to the occupant that help is on the way 5 4 4 Resetting the system When the call has been atten...

Страница 8: ...nd omissions excepted K21 Elite Security Products UK Unit 7 Target Park Shawbank Road Lakeside Redditch Worcestershire B98 8YN Tel 44 0 1527 515 150 Fax 44 0 1527 150 143 Email info espuk com Registered in England Number Company Registration No 02769392 VAT Registration GB614686525 ...

Отзывы: