background image

Doc. No.VT317

∗∗

-OMH0002-A 

 

 

 

 

 

 

 

 

3 Port Solenoid Valve 

PRODUCT NAME

 

  

 

 

VT317 Series

 

MODEL/ Series

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание VT317 Series

Страница 1: ...Doc No VT317 OMH0002 A 3 Port Solenoid Valve PRODUCT NAME VT317 Series MODEL Series...

Страница 2: ...ntents Safety Instructions 2 3 Precautions on Design 4 Selection 4 Mounting 5 Piping 5 Wiring 5 Lubrication 5 Air Supply 6 Operating Environment 6 Maintenance 6 7 Specific Product Precautions 8 Troubl...

Страница 3: ...of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectl...

Страница 4: ...lacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to u...

Страница 5: ...Vacuum When the valve is used for switching vacuum take measures to prevent suction of external dust or other contaminants from the suction pad or exhaust port 7 About ventilation When using the valve...

Страница 6: ...g or fittings into ports ensure that chips from the pipe threads and sealing material do not get inside the valve Also when the pipe tape is used leave 1 5 to 2 threads ridges exposed at the end of th...

Страница 7: ...essed Air Purification System Operating Environment 1 Do not use in atmospheres where the valve is in direct contact with corrosive gases chemicals salt water water or steam 2 Products with IP67 based...

Страница 8: ...ed Operate after safety is confirmed 1 Drain flushing Remove drainage from air filters regularly 2 Lubrication Be sure to continue to supply lubricant once it has been started And use turbine oil Clas...

Страница 9: ...lock nut 1 Bleed port 1 A bleed port for the main valve is located at the bottom of the solenoid valve Since blocking it causes malfunction do not block it Ordinarily when the solenoid valve is mounte...

Страница 10: ...completely shifted Poor seal on actuator cylinders etc side Air leaks out of connection port Burnt coil Higher voltage or wrong coil used Coil splashed by water Swollen spool Blown fuse of disconnect...

Страница 11: ...yer The valve should be replaced Check voltage Replace valve Replace worn spool To remove foreign matter air blow piping then replace valve Repair or replace actuators Isolate the valve and re tighten...

Страница 12: ...MX 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation o...

Отзывы: