background image

7” Square Hotplate

Preface 

Welcome to  the  “7”  Square  Hotplate  User  Manual”. Users 

should  read  this  Manual  carefully,  follow  the  instructions 

and procedures, and be aware of all the cautions when using 

this instrument.   

Service 

When help needed, you can always contact the Service 

Department of manufacturer for technical support. 

Please provide the customer care representative with the 

following information

 

• Serial number

on the rear panel

Certification

• Description of problem (i.e., hardware or software)
• Methods and procedures adopted to resolve the problems
• Your contact information

Warranty 

This  instrument  is  warranted  to  be  free  from  defects  in 

materials  and  workmanship  under  normal  use  and  service, 

for  a  period  of  24  months  from  the  date  of  invoice.  The 

warranty is extended only to the original purchaser. It shall 

not apply to any product or parts which have been damaged 

on  account  of  improper  installation,  improper  connections, 

misuse, accident or abnormal conditions of operation. 

For  claims  under  the  warranty  please  contact  your  local 

supplier.  You  may  also  send  the  instrument  directly  to 

manufacturer,  enclosing  the  invoice  copy  and  by  giving 

reasons for the claim.

Содержание SCI550-H

Страница 1: ... LED Digital 7 Square Hotplate Please read the User Manual carefully before use and follow all operating and safety instructions We cannot be responsible to inform at real time if the outline and specifications are subject to change for improvement ...

Страница 2: ...iving Inspection 3 3 2 Listing of Items 3 4 Control 4 4 1 Control elements 4 4 2 Display 5 5 Trial run 5 6 Working with external temperature sensor 6 7 Residual heat warning 6 8 Faults 7 9 Maintenance and Cleaning 7 10 Associated standards and regulations 8 11 Specifications 9 12 Ordering information 10 ...

Страница 3: ...e or software Methods and procedures adopted to resolve the problems Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the original purchaser It shall not apply to any product or parts which have been damaged on account o...

Страница 4: ...the media used Be aware of hazards due to unsafe container Process pathogenic materials only in closed vessels Check the instrument and accessories prior to each use Do not use damaged components Safe operation is only guaranteed with the accessories described in the Accessories chapter Accessories must be securely attached to the device and can not come off by themselves Always disconnect the plu...

Страница 5: ...suitable for using in residential areas or other constraints mentioned in Chapter 1 3 Inspection 3 1 Receiving Inspection Unpack the equipment carefully and check for any damages which may have arisen during transport Please contact manufacturer supplier for technical support Note If there is any apparent damage to the system please do not plug it into the power line 3 2 Listing of Items The packa...

Страница 6: ...ons Temperature control knob The heating function is switched ON or OFF by rotating knob LED Display If rotate the heating knob LED displays the temperature setting value and shift to real value in the duration of 5 seconds LED Heat When the heating function is switched ON the LED Heat flash Power Switch Switch ON or OFF the instrument Table 2 ...

Страница 7: ...s Hot otherwise LED displays 0 5 Trial run Make sure the required operating voltage and power supply voltage match Ensure the socket must be properly grounded Plug in the power cable ensure the power is on and begin initializing Place vessel on the work plate Set the target temperature and start heating Stop the heating functions If these operations above are normal the device is ready to operate ...

Страница 8: ...witch OFF the instrument Ensure the external temperature sensors is inserted in the media heated Switch ON the instrument and run heating function If the heating function did not work please contact manufacturer supplier for technical support 7 Residual heat warning In order to prevent the risk of burns from a hotplate digital hotplate has a residual heat warning function When the heating function...

Страница 9: ...ng tenside Isopropyl alcohol Cosmetics Water containing tenside Isopropyl alcohol Foodstuffs Water containing tenside Fuels Water containing tenside Wear the proper protective gloves during cleaning of the instrument Before using other method for cleaning or decontamination the user must ascertain with the manufacturer that this method will not harm the instrument Send in the case of service the i...

Страница 10: ...e equipment NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in a...

Страница 11: ...ment 5 Temperature display C LED Temperature display accuracy C 1 Control accuracy of heating temperature C 10 The safety temperature of the hotplate 580 Temperature sensor in medium PT1000 Control accuracy of heating temperature with temperature sensor 0 5 Residual heat warning 50 Dimensions mm 215 360 112 Weight kg 3 8 Permitted ambient temperature C 5 40 Permitted relative humidity 80 Protectio...

Страница 12: ...plug 200 240V 50Hz 60Hz 51212122xxxx SCI550 H LED Digital 7 Square Hotplate glass ceramics hotplate Euro plug 200 240V 50Hz 60Hz 51212132xxxx SCI550 H LED Digital 7 Square Hotplate glass ceramics hotplate UK plug 200 240V 50Hz 60Hz Accessories 18900016 PT1000 A Temperature sensor for digital hotplate model length of 230mm 18900136 PT1000 B Glass coated temperature sensor for digital hotplate model...

Страница 13: ...SCILOGEX LLC 1275 Cromwell Ave Suite C6 Rocky Hill CT 06067 USA Tel 1 860 436 9221 Fax 1 860 436 9745 info scilogex com www scilogex com ...

Отзывы: