2. Proper Use

The  instrument  is  designed  for  mixing  sticky  substance  in 

schools,  laboratories  or  factories.  It  can  be  installed  on  a 

variety  of  impeller,  for  different  viscosity  of  the  medium.

 

This instrument is not suitable for using in residential areas 

or other constraints mentioned in Chapter 1. 

Do  not  use  the  accessories  recommended  by  the 

manufacturer,  or  failure  to  use  the  instructions,  may  be 

caused unsafe situation. 

3. Inspection

3.1 Receiving Inspection 

Unpack the instrument carefully and check for any damages 

which may have arisen during transport. If it happens, 

please contact manufacturer/supplier for technical support. 

Note: 

If  there  is  any  apparent  damage  to  the  system, 

please do not connect to the power line. 

3.2 Listing of Items 

Items 

Qty

 

Main unit 

Power cable 

User manual 

Table 1 

Содержание SCI-T6-Pro

Страница 1: ...T6 Pro SCI T6 S LCD Digital Tube Roller Analog Tube Roller Please read the User Manual carefully before use and follow all operating and safety instructions Technical specifications and outline are subject to change without prior notice www scilogex com ...

Страница 2: ...roper Use 3 3 Inspection 3 3 1 Receiving Inspection 3 3 2 Listing of Items 3 4 Control and Display 4 4 1 Control 4 4 2 Display 5 5 Operation 6 6 Faults 6 7 Maintenance and Cleaning 7 8 Associated standards and regulations 7 9 Specifications 8 10 Ordering Informations 8 ...

Страница 3: ...umber on the rear panel Certification Description of problem i e hardware or software Methods and procedures adopted to resolve the problems Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the original purchaser It shal...

Страница 4: ...tmospheres with hazardous substances or under water If the instrument does not run smoothly please decrease the motor speed Firmly secure the accessories and vessels in place to avoid damage or risk Preparation of samples may lead to dangerous flammable Only process samples that will not react dangerous Use the standard accessories listed in the accessories section and follow the instructions to u...

Страница 5: ...r 1 Do not use the accessories recommended by the manufacturer or failure to use the instructions may be caused unsafe situation 3 Inspection 3 1 Receiving Inspection Unpack the instrument carefully and check for any damages which may have arisen during transport If it happens please contact manufacturer supplier for technical support Note If there is any apparent damage to the system please do no...

Страница 6: ...olors of LED light show the value for speed or time that LCD screen currently displays Green LED light shows that LCD screen currently displays speed Red LED light shows that LCD screen currently displays time Power Overload protection light Power Overload Green Red LED display light LED light shows green when switch on LED light shows red when starts overload protection When the torque reaches li...

Страница 7: ...ntrol knob to start stop rotating function Power light Green LED display light Power LED light shows green when switch on Power switch I O Switch ON or OFF the instrument Table 3 4 2 Display Figure 3 Display Descriptions Set Display when set target value Err Display in case of error happening Display area When Set display this area shows setting value When Set disappears this area shows running va...

Страница 8: ...opped at any time by pressing the speed timer control knob If the knob is pressed again motion will start again and the timer will restart countdown When the timer reaches zero the unit will be automatically halted and an alert will sound If these operations above are normal the instrument is ready to operate If not the instrument may be damaged during transportation please contact technical suppo...

Страница 9: ...e user must ascertain with the manufacturer that this method will not damage the instrument Wear the proper protective gloves during cleaning of the instrument Note Electronic device cannot clean with cleanser If you require maintenance service must be cleaned the instrument in advance to avoid pollution of hazardous substances and to send back into original packing If the instrument will not use ...

Страница 10: ...requency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 9 Specifications Items Specifications LCD digital model Classic model Voltage VA...

Страница 11: ...rs 100V 240V 50HZ 60HZ Cn plug 823222219999 SCI T6 Pro LCD Digital Tube Roller variable speed 6 rollers 100V 240V 50HZ 60HZ Euro plug 823222319999 SCI T6 Pro LCD Digital Tube Roller variable speed 6 rollers 100V 240V 50HZ 60HZ UK plug 823220019999 SCI T6 S Classic Tube Roller variable speed 6 rollers 100V 240V 50HZ 60HZ US plug 823220119999 SCI T6 S Classic Tube Roller variable speed 6 rollers 100...

Страница 12: ...SCILOGEX LLC 1275 Cromwell Ave Suite C6 Rocky Hill CT 06067 USA Tel 1 860 436 9221 Fax 1 860 436 9745 info scilogex com www scilogex com ...

Отзывы: