1  Safety Instructions 

Warning! 

Read  the  operating  instructions  carefully

before use.

Ensure  that  only  trained  staff  work  with  the

instrument.

Risk of burn! 

Caution  when  touch  the  housing  parts  and

the  hotplate  which  can  reach  temperature  of

340°C.

Pay  attention  to  the  residual  heat  after

switching off.

Protective ground contact

 

Make  sure  that  the  electrical  socket  is

grounded  (protective  ground  contact)  before

use.

• When  operating  wear  personal  safety  protection  to  avoid

the risk from: 

- Splashing and evaporation of liquids 

- Release of toxic or combustible gases 

• Use  the  instrument  in  a  spacious  area  on  a  stable,  clean,

non-slip,  dry  and  fireproof  surface.  Do  not  operate  the 

instrument in explosive atmospheres, with hazardous   

substances or around water. 

• Gradually increase the speed, reduce the speed if:

- Stirring bar breaks away due to high speed 

-  The  instrument  is  not  running  smoothly,  or  the  container 

is not centered on the plate 

• Temperature must always be set to at least 50C lower than

the flash point of the media used. 

• Be aware of hazards due to:

-  Flammable  materials  or  media  with  a  low  boiling 

temperature 

- Overfilling of media 

- Unsafe container 

• Process pathogenic materials only in closed vessels.

• If the case of the stirrer bar is PTFE, please note

-  Elemental  fluorine,  three  fluoride  and  alkali  metals  will 

corrode  the  PTFE  and  Halogen  alkanes  make  it  expand  at 

room temperature 

-  Molten  alkali

alkaline  earth  metals  or  their  solution,  as 

well  as  the  powder  in  second  and  third  ethnic  of  the 

Periodic  Table  of  Elements  will  have  chemical  reaction 

with PTFE when temperature reaches 300 ~ 400C . 

• Check  the  instrument  and  accessories  prior  to  each  use.

Do not use damaged components. Safe operation is only   

guaranteed  with  the  accessories  listed  in  the  “Accessories” 

Содержание MS-H-Pro-T

Страница 1: ...imer Please read the User Manual carefully before use and follow all operating and safety instructions Technical specifications and outline are subject to change without prior notice www scilogex com...

Страница 2: ...ontrol 4 4 1 Control elements 4 4 2 Display 6 5 Trial Run 6 6 Function Heating 7 6 1 Working with the PT1000 external temperature sensor 8 6 2 Residual heat warning HOT 8 7 Stirring 9 8 Timer 9 9 Remo...

Страница 3: ...ion Serial number on the rear panel Certification Description of problem i e hardware or software Methods and procedures adopted to resolve the problems Your contact information Warranty This instrume...

Страница 4: ...reduce the speed if Stirring bar breaks away due to high speed The instrument is not running smoothly or the container is not centered on the plate Temperature must always be set to at least 50C lowe...

Страница 5: ...be operated by adults Keep away from high magnetic fields 2 Proper Use The instrument is designed for mixing and or heating liquids in laboratories Do not use more than 2000 meters above sea level Te...

Страница 6: ...parent damage to the unit do not attempt to operate 3 2 Listing of Items The package includes the following items Items Qty Main unit 1 Power cable 1 Stirrer bar 1 User Manual 1 Table 1 4 Control 4 1...

Страница 7: ...f Parameter setting knob At the parameter setting interface set the parameter by turning the knob Pressing the knob turns on the initializer LCD display LCD displays the real time working state and al...

Страница 8: ...sing remote control Rated value Real value Display values in when heating or stirring or timer function is switched ON Table 3 Note If both heating and stirring functions have been started at the same...

Страница 9: ...rcuit The hotplate temperature can also be controlled from a separate adjustable safety circuit The two temperature sensors PT1000 internal for temperature control are built into the hotplate The sing...

Страница 10: ...ature more precisely The external temperature sensor must be put in sample container if detect anomalies heating will automatically shut down Please do the following at this time Turn off the power En...

Страница 11: ...he parameter set knob to target time press parameter set knob to switch on timer function Attention The heating and stirring function can be switched on at the same time only when setting the timer fu...

Страница 12: ...the residual heat warning function is still ON and hotplate temperature is above 50 the LCD still work and Hot flash If these faults are not resolved please contact manufacturer supplier 11 Maintenan...

Страница 13: ...following safety standards EN 61010 1 UL 3101 1 CAN CSA C22 2 1010 1 EN 61010 2 10 Construction in accordance with the following EMC standards EN 61326 1 Associated EU guidelines EMC guidelines 89 33...

Страница 14: ...l with ceramic coated Dimensions of workplate mm 135 Heating power W 500 Temperature range C Room temperature 340 Step 1 Temperature display C LCD Temperature display accuracy C 0 1 The safety tempera...

Страница 15: ...0V 240V 50Hz 60Hz Cat No Descriptions Accessories 18900016 PT1000 A Temperature sensor for digital hotplate model used for MS H Pro MS H ProT MS7 H550 Pro MS7 H550 S length of 230mm 18900136 PT1000 B...

Страница 16: ...tion block for 500ml round bottom flask one flask capacity 18900006 Stirrer bar 10mm x 6mm 1pc pk 18900007 Stirrer bar 15mm x 8mm 1pc pk 18900008 Stirrer bar 20mm x 8mm 1pc pk 18900009 Stirrer bar 25m...

Страница 17: ...SCILOGEX LLC 1275 Cromwell Ave Suite C6 Rocky Hill CT 06067 USA Tel 1 860 436 9221 Fax 1 860 436 9745 info scilogex com www scilogex com...

Отзывы: