Troubleshooting
Error Codes
–
Red flashing light with a repeating pattern of blinks and a delay
Number of
red blinks
Reason
Action
1
Lamp current out of range
Check for a loose or broken lamp
2
Drop detected
Press stop to reset and start without
motion after the delay
3
Temperature out of range
Low Temp
–
warm vehicle above 36⁰F
High Temp
–
Allow tool and vehicle to
cool below 113⁰F
4
Battery level low
Recharge battery
5
Process stopped due to low battery
Recharge battery
Problem
Possible Cause
Solution
Does not power on
Battery loose or needs charging
Remove the battery and check
the level by pressing the button
on the battery. The tool needs 1
or more bars to run the process.
Make sure battery fully ‘clicks’
into place when attaching to
mount
Fan won’t shut off
Temperature is higher than
81⁰F
It’s ok to turn th
e power switch
off before the fan turns off. The
tool will cool naturally.
Lamps are not operating
Loose or broken lamp
See the instructions in the
maintenance section
Tool does not shut off after 25
minutes
Controller error
Wait for the battery to
discharge or release the cam
lock on the strap to let the tool
drop to seat and shut-off.
Contact service
No green light after process run
Green light goes off after 30
minutes to save power
No action
Содержание Ultra254 950