APPENDIX N
MODEL 5000 SERIES MANUAL
Version 1.23
13-67
for the relay form factor and number of poles are provided along with selections for
start and stop percentages and step time for use with the Datalog/Measure mode.
Go/No-Go Test Sequence:
Check that all contacts are in the non-operate position
Drive the relay coil to the VOPER voltage
Wait the specified Step Time
Check that all contacts are in the operate position
Drive the relay coil to the Limit entry
Check that all contacts have switched back to the non-operate position
Datalog/Measure Sequence:
Check that all contacts are in the non-operate position
Drive the relay coil the Start Voltage (Limit Entry times the Start Volts entry)
Wait the specified Step Time
Check that all contacts are in the operate position
Decrement the applied coil voltage by the specified Step Volts and drive the
relay coil
Wait the specified Step Time
Check to see if all of the relay contacts have switched to the non-operate
position
Repeat above two steps until all contacts have switched back to the non-
operate position or the Stop Voltage has been reached.
Report the voltage at which all of the contacts have switched back to the
non-operate position
R
CONT
Test
The R
CONT
test measures the contact resistance. An A-Form relay contact resistance
is measured by first applying the V
COIL
voltage; then applying the contact current,
I
CONT
. A C-Form relay contact resistance is measured in the non-operated position
first, then the V
COIL
voltage is applied, then the contact resistance is measured in the
operated position and the higher of the two readings is reported.
OP
TIME
Test
The OP
TIME
test determines the time required for the relay contacts to close after the
specified coil voltage is applied. The resolution for this test is ±50
μS.
REL
TIME
Test
The REL
TIME
test determines the time required for the relay contacts to open after the
specified coil voltage is removed (the coil voltage is applied and contact closure is
confirmed). The resolution for this test is ±50
μS.
Notes
A relay with the contacts welded in the operated position can be determined by
checking that it fails V
REL
and REL
TIME
and passes R
CONT
(A-Form) or fails R
CONT
(C-
Form).
A relay with contacts welded in the non-operated position can be determined by
checking that it fails V
OPER
, OP
TIME
and R
CONT
(both a-Form and C-Form).
All tests report the worst case answer if more than one pole.
Содержание 5000 Series
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 30: ...TABLE OF CONTENTS xx Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 38: ...1 OVERVIEW 1 8 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 52: ...3 THEORY 3 6 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 56: ...4 SPECIFICATIONS 4 4 Version 1 23 MODEL 5000 SERIES MANUAL 4 4 Model 5300HX Test Specifications ...
Страница 62: ...4 SPECIFICATIONS 4 10 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 64: ...5 BASIC OPERATION 5 2 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 102: ...6 PC SOFTWARE 6 38 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 218: ...7 MAINTENANCE TROUBLESHOOTING 7 116 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 226: ...8 LOW CURRENT DECK 8 8 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 234: ...10 PIN PROGRAMMABLE SCANNER 10 4 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 242: ...APPENDICES 13 2 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 244: ...APPENDIX A 13 4 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 250: ...APPENDIX C 13 10 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 252: ...APPENDIX D 13 12 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 254: ...APPENDIX E 13 14 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 258: ...APPENDIX F 13 18 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 262: ...APPENDIX G 13 22 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 268: ...APPENDIX H 13 28 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 289: ...APPENDIX I MODEL 5000 SERIES MANUAL Version 1 23 13 49 Figure 13 39 10x1000 Pulse Option Calibration Screen ...
Страница 290: ...APPENDIX I 13 50 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 292: ...APPENDIX J 13 52 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 296: ...APPENDIX K 13 56 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 304: ...APPENDIX M 13 64 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 308: ...APPENDIX N 13 68 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 312: ...APPENDIX P 13 72 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 316: ...14 APPLICATION NOTES 14 2 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 318: ...APP 001 14 4 Version 1 23 MODEL 5000 SERIES MANUAL Figure 14 2 APP 001 Test Screen ...
Страница 320: ...APP 001 14 6 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 322: ...APP 002 14 8 Version 1 23 MODEL 5000 SERIES MANUAL Figure 14 6 APP 002 Bin Sort Screen ...
Страница 324: ...APP 003 14 10 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 326: ...APP 004 14 12 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 332: ...APP 006 14 18 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 336: ...APP 007 14 22 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 338: ...APP 008 14 24 Version 1 23 MODEL 5000 SERIES MANUAL ...
Страница 340: ...APP 009 14 26 Version 1 23 MODEL 5000 SERIES MANUAL ...