43
Overview
SPB Operation Manual
Setting Joystick Min/Max Speeds
PWM outputs are adjustable and should be tuned to
control the valves through their entire range of motion.
To obtain optimal function movement in relation to the
joystick deflection, the adjustments should be made
during operation. The following steps outline how to ad-
just the functions:
1. Remove the battery from the Transmitter. Tether
Transmitter to the Control Panel with the provided
Connection Cable
Transmitter
Figure 4
Tether Transmitter to Control Panel
2. Press and release the E-Stop button on the radio
remote.
3.
Ensure all switches are in the neutral or off posi
-
tions.
4. Press and hold the power button until the LED illu-
minates solid red - within 5 seconds, tap the rabbit
switch in quick succession until the remote gives a
long beep. The ID window in the receiver will dis-
play Po:00. Release the power button.
=
E-Stop
Power Button
Power LED
Stroke Limiter
Snail / Rabbit Switch
Figure 5
Transmitter switches and buttons
5. Press and release the power button to increment
to the next PO number in the table. Receiver LED
display will increment with each press.
The transmitter will also beep indicat-
ing the current PO number selected
and flash the antenna LED.
Description
PO Number Notes
Not Used
Po:00
Direction (not used)
Po:01
Inverts the direction of a function
(00=Normal, 01=Flipped)
Min Value
Po:02
Adjust the start/min value of an Output
Max Value
Po:03
Adjust the stop/max value of an Out-
put
Slow Speed%
Po:04
Adjust the first speed % value
Unused
Po:05 - 15
After Po:15 returns back to Po:00
6. With the joysticks released, press and release the
power button until the desired Po: number is dis
-
played.
E.g. to adjust the minimum value of a func-
tion select Po:02
=
7. To adjust a function, move the desired joystick. The
receiver LED will display the function number
e.g.
1A,
followed by the current value of the parameter
being adjusted
e.g. 40
.
Only move one function
at a time!
=
In the above example, the start speed for output 1A
(Slew Clockwise) is set to 40% of the maximum current.
8. Press the Snail / Rabbit Switch left (+) and right
(-) to increase and decrease the boom speed. The
receivers LED will change, showing the current
value. The function should be moving while the
value is being adjusted to observe the change in
speed. Keep in mind, the joystick is still proportion-
al during calibration.
9. Repeat steps 7 and 8 for all minimum values that
need adjusting. Then press the power button to in-
crement to the maximum value: Po:03 and repeat.
Slow speed % is typically not adjusted.
Содержание SPB 28
Страница 2: ......
Страница 4: ......
Страница 8: ...8 Table of Contents SPB Operation Manual...
Страница 10: ......
Страница 16: ...16 Introduction SPB Operation Manual...
Страница 18: ......
Страница 22: ...22 Specifications SPB Operation Manual SPB 35 Working Range Diagram SPB 35 235...
Страница 24: ...24 Specifications SPB Operation Manual Working Range Diagram SPB 37 SPB 37 235...
Страница 26: ......
Страница 28: ...28 Safety S 39 41 SX Operation Manual...
Страница 113: ...402indexcov eps ALPHABETICAL INDEX 700indxcov fm PAGE 83 SAFETY MANUAL Alphabetical Index...
Страница 122: ...30 Overview S 39 41 SX Operation Manual...
Страница 154: ...62 Operation SPB Operation Manual Lifting Instructions 1 of 3...
Страница 155: ...63 Operation SPB Operation Manual Lifting Instructions 2 of 3...
Страница 156: ...64 Operation SPB Operation Manual Lifting Instructions 3 of 3...
Страница 200: ......
Страница 216: ...124 Appendix SPB Operation Manual...