Electrode Inverter | Version 1.09
Description of the operating elements
7
Description of the operating
elements
7.1 Representation
EASY-STICK 121, EASY-STICK 141 and EASY-STICK
161:
Fig. 4: Device view EASY-STICK 121, EASY-STICK 141 and EASY-
STICK 161
1 „+“ - Output terminal
2 „-“ - Output terminal
3 LED: Power indicator, Lamp lights up when in
operation
4 LED: Alarm indicator
5 Welding current adjustment knob
6 Mains connection (Back side)
7 ON/OFF switch (Back side)
Alarm indicator (4):
Lights up in case of current overload, overvoltage, over-
heating, mains failure or internal defect in the power cir-
cuit. The device protection is activated. The welding cur-
rent is switched off until the system detects that the
overload has been significantly reduced. The alarm dis-
play then goes out.
Welding current adjustment knob (5):
The desired welding current can be set steplessly with
the welding current adjustment knob (5).
Fig. 5: Control panel EASY-STICK 161
7.2 Scope of delivery
EASY-STICK 121:
- Electrode Inverter
- 3 m welding cable 12 mm² with electrode holder
- 3 m earth cable 12 mm² with ground clamp 200 A
- Operating instructions
EASY-STICK 141:
- Electrode Inverter
- 3 m welding cable 16 mm² with electrode holder
- 3 m earth cable 16 mm² with ground clamp 200 A
- Operating instructions
EASY-STICK 161:
- Electrode Inverter
- 3 m welding cable 16 mm² with electrode holder
- 3 m earth cable 16 mm² with ground clamp 200 A
- Operating instructions