background image

www.schweigen.com.au

RANGEHOOD & INSTALLATION GUIDE

WM-EX90S

Revision V3

  01/10/21

Содержание WM-EX90S

Страница 1: ...www schweigen com au RANGEHOOD INSTALLATION GUIDE WM EX90S Revision V3 01 10 21 ...

Страница 2: ...the Lights 11 6 Installation 12 Drop Down Side Doors 12 Rangehood Size vs Cooktop Size 12 Mounting Instructions 13 Recommended Installation Height for Induction Cooktop 13 Attaching the Computer Board and wiring Bracket Certain models only 14 Installation Guide 15 Ducting 18 Back Draft Fins For applicable models 18 System Overview 19 7 Condensation Information 20 Cooking with Induction Cooktops 20...

Страница 3: ... website www schweigen com au This appliance and its packaging are produced by processes that minimise waste and respect the environment Please help us to continue this effort to protect the environment by using the appliance efficiently and dispose of the packaging in a responsible manner We trust that you will enjoy your new Schweigen rangehood Your State Regulatory Authority Different Australia...

Страница 4: ...y person s including children with reduced physical sensory or mental capabilities or lack of experience and or knowledge Unless the person has been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance it is not a toy 8 Exhaust air must not be discharged into an...

Страница 5: ...s are made by a qualified technician and that the indicated instructions and local regulations in force are met using materials that are compliant with the applicable legislation 11 The company will not be responsible for installations executed by non qualified staff and installations that fail to heed the applicable legislation on electrical safety with regard to both modes and materials 12 The e...

Страница 6: ...iling cavity When a rangehood is ducted only into the ceiling space the collection of humidity and grease can present very real health issues and fire hazards Recirculating or non ducted or filtered rangehoods extract cooking fumes and pass them through filters As the name would suggest they recirculate this air back into the room Recirculating rangehoods are not as effective as removing fumes fro...

Страница 7: ...ain Power 240V 8 Reducer For Isodrive 650 motor only 9 Filters 10 Screw Pack 11 Light NOTE Filter and light quantity may vary from model to model Important Electronics MUST be accessible for service and or maintenance once installed failure to do so will result in any charges involved with accessing the part removal of cabinetry etc being forwarded to the customer 1 2 3 4 5 7 6 8 9 10 11 ...

Страница 8: ... at which is was turned off D Reduce speed This button reduces the aspiration speed When in operation the low speed button will be blue E Light Press this button to turn the lights on and off When the lights are operating the light button is blue This rangehood has a device that lets you know when the grease filters must be cleaned When the light button E flashes this means the filters must be was...

Страница 9: ...ap to not contain granules that could scratch the surface First apply the solution to a soft cloth and then rub the cloth over the rangehood It is important to follow the direction of the stained surface with the cloth refer to figure on left Do not pour any liquid directly on to the rangehood The cloth must have no buttons zips or fasteners that could scratch the surface It is strictly forbidden ...

Страница 10: ...rs may change after several washes This is normal and it is not necessary to change the filters Please ensure the filters are completely dry before placing them back in position and operating the rangehood Warning If the grease filters are very dirty the motor will extract only a small quantity of air which reduces its efficiency The grease deposits that build up on the filter are highly flammable...

Страница 11: ...hed off Step 2 Unplug the red and black wires by pushing the clips A and pulling the cord Step 3 Push the 2 clips on the side of the light B and gently push down The light will then come out Step 4 Insert the new light by pushing into the cavity into the light clips in Plug in the red and black wires into their respective slots Step 5 Replace the filters and close the perimiter aspiration door Ste...

Страница 12: ...btain the best performance INADEQUATE Rangehood smaller than cooking zone ADEQUATE Rangehood same size as cooking zone OPTIMAL Rangehood larger than cooking zone Drop Down Side Doors This rangehood has drop down glass side doors allowing more control and optimised ventilation They can deflect air that may interfere with rangehood extraction ...

Страница 13: ...hweigen recommends a height between 700 750mm Refer to page 19 for further information IMPORTANT If the user decides to install the rangehood at a distance of less than minimum height above the cooking surface Schweigen declines responsibility for damages suffered by the rangehood due to excess heat or damage to objects people and others caused directly or indirectly by a malfunction breakage or f...

Страница 14: ... you may need to connect the computer board and wiring bracket to the main body of the rangehood 1 Attach the computer board to the outlet box using the screws provided 2 Position the computer board facing out from the outlet see figure A align the holes when attaching the computer board figure B and secure using screws provided NOTE Some of the models only have two screw holes Computer Board ...

Страница 15: ...velling screw points B Main support bracket wall screw points C Second rangehood screw points D Main support bracket B A D C Step 1 Measure the position on the wall where the bracket is to be inserted following the height recommendations indicated in the mounting laws and regulations section Draw a line and mark the position of the holes that must be made make sure it is level and fixed D to a sup...

Страница 16: ...angehood outlet to the Isodrive motor The reducer is to be placed on top of the 200mm outlet on the rangehood when using a 650 Isodrive motor only Step 5 Place flue covers onto the rangehood and adjust the height of the flue covers by sliding the outer flue cover down NOTE The outer flue cover section alone will not cover the entirety of the control box and PCB computer board A C Inner flue cover ...

Страница 17: ...all flue bracket 1 Fold both ends to 90 as shown figure 1 2 Install the bracket to the wall at the correct height see figure 2 3 Attach flue cover to the bracket see figure 3 _n_ _RH Section_ Page 17 6 Installation IMPORTANT Please ensure all plastic protection on the rangehood and filters is removed before use ...

Страница 18: ...ls The supplied ducting has been manufactured with an allowance for the back draft fins to operate without hindrance It is the smooth extended end of the ducting When installing Back Draft Fins please ensure that you insert the Back Draft Fins onto the back draft base which are attached to the top of the motor outlet before installation Then place the smooth extended edge of the ducting into the b...

Страница 19: ...exi Ducting must be pulled taut DO NOT crush or kink the ducting 9 Connect flexi ducting to the outlet on rangehood using ring clamp Please DO NOT rip the ducting Pictures are for illustrative purposes only not to scale 1 2 3 4 5 6 7 8 9 DANGER All electrical wiring from the motor to the rangehood should be kept inside the roof space NOTE The Isodrive motor system does not include the roof seal ki...

Страница 20: ...from cooktop to the rangehood Speed of food liquid heating Filter size larger canopy preferred Quality of pots or cookware you are using high quality recommended How to reduce the possibility of condensation forming Ensure the rangehood is installed by a qualified professional carefully following the installation guide Turn on the rangehood 5 10 minutes prior to cooking and leave on for 10 15 minu...

Страница 21: ...ht bulbs should be firmly in position Check light bulbs Make sure they are not broken or faulty Please make sure there is no obstruction in ducting or with the back draft fins Check the outlet make sure it is not blocked and you have the correct diameter ducting installed Check Isodrive installation manual make sure the flexi ducting is installed correctly eg Length of ducting used keep the ductin...

Страница 22: ...he appliance at their expense Service Lodging an Online Service Request In the event that the failure is not due to the faults mentioned in the Troubleshooting section you can lodge an online Service Request To lodge an online Service Request visit our website www schweigen com au service and warranty and click on the link and complete the service request form A service request will require the fo...

Страница 23: ...e 23 9 Specifications Technical Specifications Model WM EX90S Feeding Voltage 220 240V 50Hz Lamp Power LED W 3 x GLED Square 55 x 55mm 2 1 Watts 12V 4000k Dimensions 900 440 Min 620 Max 1050 520 300 300 80 ...

Страница 24: ... with the Isodrive Motor or online at schweigen com au Schweigen Home Appliances has presented this information in good faith to all their retailers and distributors to convey before any all purchase s Information is supplied upon the condition that the person s receiving the information will make their own determination as to its suitability for their purpose s prior to use In no event will Schwe...

Страница 25: ...Page 25 Notes ...

Страница 26: ...Page 26 Notes ...

Страница 27: ...Page 27 Notes ...

Страница 28: ...Drive Dingley Village Victoria 3172 Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emerson com Web www parex co nz ...

Отзывы: