Troubleshooting
05.00|1411420_NSE-HT mini 88-20, NSE-HT mini 88-20-V1 |en-US
35
Troubleshooting
The clamping area does not unlock
Possible cause
Remedial measures
Defective air connections
Check air supply
Pressure below minimum
Check operating pressure (min. 5 bar)
A component is broken (e.g. due to
overloading)
Replace the clamping module or send it to
SCHUNK for repair
Excess tensile load on clamping pins
Reduce tensile load on clamping pins
The turbo connection is still pressurized Ventilate the connection
Leakage due to worn seal
Check for leaks
. In case of
leakage send the clamping module to SCHUNK
for repair
If the clamping area does not unlock perfectly
Possible cause
Remedial measures
Pressure below minimum
Check operating pressure (min. 5 bar)
Hose diameter below minimum
For required hose diameters, see chapter
The turbo connection is still pressurized Ventilate the connection
The quick-change pallet system no longer opens quietly
Possible cause
Remedial measures
The clamping faces on the clamping slides
and on the clamping pin are dirty
Remove the clamping pin and clean the
clamping faces on the clamping slides and on
the clamping pin
Leakage due to worn seal
. In case of
leakage, send the clamping module to SCHUNK
for repair.
8
8.1
8.2
8.3