Assembly
20
05.00|0489065 KSH plus, KSH-LH plus, KSH-F plus |en
NOTE
• For vertical installation, the opening of the coolant drain (item
13) must always face downwards
• Surface
"X"
is parallel to the guideway of the base jaws (item 2)
so the clamping block can be aligned on the machine table.
Assembly with clamping sleeves:
Mount the clamping block on the machine table together with
clamping sleeves (item 27) and screws (item 19).
Assembly with fitting screws:
There are two fittings in the housing (item 1) that, along with the
optional fitting screws (item 9), are used to center the clamping
block on the machine table with repeat accuracy. Do not realign
the clamping block after removing it from the machine table (e.g.,
after replacing the seals). When using fitting screws (item 9), use
them instead of the clamping sleeves (item 27) and the two
corresponding screws (item 19).
Connecting the clamping block
Make sure the power supply is off when connecting the clamping
block. Observe the "Basic safety notes" and the hydraulic wiring
diagram
.
The hydraulic screw fittings must be assembled in accordance
with the installation conditions recommended by the
manufacturer.
For the operation of the clamping block, the hydraulic oil must
correspond to a viscosity of 46 mm/s, and be filtered.
Hydraulic
oil that is not prepared can wear out the clamping block
prematurely and lead to malfunctions.
CAUTION
Risk of work piece losses and damage to the automated system
due to loss of oil pressure caused by damaged hydraulic lines.
Always make sure the connections are tight, and protect the
hydraulic hoses or lines against hot chips and falling parts with
suitable protection covers.