Assembly
58
12.00 | SWS | Assembly and Operating Manual | en | 389456
5.3 Pneumatic connection
CAUTION
Material damage due to loss of compressed air!
The SWA can become loose in the event of a loss of compressed
air, but the connection between SWK and SWA is ensured by a
patented self-locking
mechanism. The SWK can then no longer
decouple a coupled SWA or accept a new SWA. A loss of
compressed air leads to increased wear.
•
End the fail-safe operation as soon as possible. To do this,
restore the compressed air supply or stop operation of the
machine/automated system to eliminate the cause of the
failure.
•
After a fail-safe operation, check the system for damage and
monitor the resumption of normal operation for proper
functioning.
NOTE
Observe the requirements for the compressed air supply,
5.3.1 Example for pneumatic control
Locking
Unlocking
Air connection (4.5-6.9 bar)
Exhaust
4 or 5-way valve
SWK, illustration unlocked, shown as an example on SWK 110