Technical Data
04/STM-560V/en/2010-12-10/SW
25
The additional technical data presented in the data sheet for
valve MV15 must also be observed.
Note
If there is a low level signal from the controller pending on the
valve, the electropneumatic brake valve is closed. In this state,
the brake is active.
If there is a high level signal from the controller pending on the
valve, the electropneumatic brake valve is opened. In this state,
the brake is inactive.
6.3.2
Connection to Bosch IndraDrive
Terminal
Cable color, brake valve
X6-3
+24V (red)
X6-4
0V (black)
Table 12 IndraDrive C connection
6.3.3
Connection to Siemens Safe Brake Relay
Terminal
Cable color, brake valve
BR+
+24V (red)
BR-
0V (black)
Table 13 Sinamics CU310DP connection
6.3.4
Holding brake moment
Motor type
Holding brake moment [Nm]
STM135
2.5
STM170
5
STM210
10
Table 14 Holding brake moment