Troubleshooting
05/STM-48V/en/2011-04-01/CW
67
13.1.5
Error message for the winding temperature
Possible cause
Corrective action
The electrical connection to the temperature
sensor is faulty
Check resistance between the controller and the
temperature sensor in the STM and replace the
electrical connection, if necessary.
Temperature sensor defective
Check the resistance of the temperature sensor.
If the resistance exceeds 630 Ohms at room
temperature, the STM must be sent to SCHUNK with
a repair order.
Thermal motor overload
Reduce the load.
Mount the motor on heat-conducting materials to
dissipate excess motor heat.
Rotor is blocked mechanically
Check the mechanical components.
Check the evenness at the mounting surface (see
Encoder signals are faulty;
encoder line shielding is not corrected.
Check the encoder's power supply.
Check the encoder signals and the shielding of the
encoder cable.
Motor overload;
overvoltage or undervoltage
Check the dimensioning.
Reduce the load.
Check the controller settings.
Check the output power supply.
Table 37
13.2
MCS-12 controller
13.2.1
Software error messages
The MCS-12 controller indicates the error via the flashing red
LED. To determine the error cause, the MCS-12 controller must
be connected to the PC.
Consult the operating manual, MotionControl.pdf, and rectify
the error.
Note
In an error occurs, the STM is switched and the motor's phases
are bypassed, so that an active motion of the unit via the digital
inputs is not possible any more without acknowledging ("Error
Acknowledge") the error.
Содержание STM 48V
Страница 2: ...2 05 STM 48V en 2011 04 01 CW...
Страница 73: ...Drawing 05 STM 48V en 2011 04 01 CW 73 16 Drawing 16 1 STM 135 Figure 41 Dimensions of the STM 135 torque motor...
Страница 74: ...Drawing 74 05 STM 48V en 2011 04 01 CW 16 2 STM 170 Figure 42 Dimensions of the STM 170 torque motor...
Страница 75: ...Drawing 05 STM 48V en 2011 04 01 CW 75 16 3 STM 210 Figure 43 Dimensions of the STM 210 torque motor...
Страница 77: ...Translation of original EC declaration of incorporation 05 STM 48V en 2011 04 01 CW 77...
Страница 80: ...80 05 STM 48V en 2011 04 01 CW...