Technical Data
26
05/STM-48V/en/2011-04-01/CW
The additional technical data presented in the data sheet for
valve MV15 must also be observed.
Note
If there is a low level signal from the controller pending on the
valve, the electropneumatic brake valve is closed. In this state,
the brake is active.
If there is a high level signal from the controller pending on the
valve, the electropneumatic brake valve is opened. In this state,
the brake is inactive.
6.3.2
Connection to MCS-12
When the two vales were screwed in the appropriate threads,
connect the two red cables to the clamp BR1 and the black
cables to the clamp BR2.
Terminal
Cable color, brake valve
BR1
red
BR2
black
Table 12 Connection
6.3.3
Holding brake moment
Motor type
Holding brake moment [Nm]
STM135
2,5
STM170
5
STM210
10
Table 13 Holding brake moment