Assembly
5.3 Mounting separating sleeve
CAUTION
The O-ring could be damaged!
If the set-screw is turned too far into the air connection, the O-
ring may be damaged when screwing in the separating sleeve and
the air connection may not be sealed tightly.
•
Screw set-screw out to a small extent.
•
Screw the separating sleeve carefully until the end of the
threads.
1. Screw the locking screws (3) on the apparatus side (1) out of
the air connections
A
and
B
.
2. Screw set-screws (4) out to a small extent.
3. Screw separating sleeves (2) from the accessory pack into the
air connections
A
and
B
until the end of the threads.
4. Screw in unscrewed set-screws (4) until the separating sleeve.
5. Mount hose connections
A1
,
A2
,
B1
and
B2
.
✓
Position the hose connections,
35
11.00 | SRU-plus 20 - 60 | Assembly and Operating Manual | en | 389443