![SCHUNK SRM 10 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/schunk/srm-10/srm-10_assembly-and-operating-manual_1216055022.webp)
Technical data
22
12.00 | SRM | Assembly and Operating Manual | en | 1346850
3 Technical data
3.1 Basic data, size 10 - 14
Designation
Value
Pressure medium
Compressed air, compressed air
quality according to
ISO 8573-1:7 4 4
Nominal operating pressure [bar]
6
Min. pressure [bar], SRM-E
4.5
Min. pressure [bar], SRM-H/-S
3
Min. pressure [bar], SRM-X
3
Max. pressure [bar]
6.5
More technical data is included in the catalog data sheet.
Whichever is the latest version.
The catalog data sheet contains diagrams for designing the
maximum permissible mass moment of inertia.
The SCHUNK contact person provides support for designing further
applications.
Ambient conditions and operating conditions
Designation
Value
Ambient temperature [°C]
Min.
Max.
+5
+60
Protection class IP, SRM-E /-H /-
S
40
Protection class IP, SRM-X
40
Noise emission [dB(A)]
≤ 70