Troubleshooting
01.02|SPG 100|en
23
Module opens or closes abruptly?
Possible cause
Corrective action
Too little grease in the mechanical guiding
areas of the module
Clean the module and relubricate it.
Compressed air lines are blocked
Check the compressed air lines for crushing
or damage.
Mounting surface is not even enough
Check the levelness of the bolting surface.
Flow control valve is missing or not set
correctly
Install and adjust flow control valve.
Load too high
Review permissible weight and length of the
jaws.
The gripping force drops?
Possible cause
Corrective action
Compressed air can escape
Check seals, if necessary disassemble
module and replace seals.
Too much grease in the mechanical motion
spaces of the module
Clean the module and relubricate it.
Pressure drops below minimum.
Check the air supply.