Trouble shooting
03.00|ROTA TPS-K, ROTA TPS-Z |en
25
Trouble shooting
The chuck jaws do not move
Possible cause
Corrective action
Air supply interrupted
Connections mixed up.
Check compressed air lines.
Piston will not move:
- Compressed air is not oiled.
- Maintenance unit with oiler is too far from
the chuck.
- The seal in the cover is not properly
inserted.
Install maintenance unit with oiler.
Position the maintenance unit with oiler
closer to the chuck.
Check the seal in the cover and insert
correctly.
The Clamping System does not move the full stroke?
Possible cause
Corrective action
Chips or dirt between guide bushing and
base jaws.
Completely disassemble, clean and
relubricate the chuck.
Clamping force getting weaker
Possible cause
Corrective action
The clamping system is leaking:
- Connection and/or sealing screws leaking.
- Seals damaged.
- Steel guide rollers on sliding surfaces not
greased.
Seal any leaking screws.
Disassemble chuck and replace seals
.
Lubricate the chuck with SCHUNK LINO MAX
special grease at the base jaw lubrication
nipples by means of a grease gun.
Clamping system movement jerky
Possible cause
Corrective action
Steel guide rollers on sliding surfaces not
greased.
Lubricate the chuck with SCHUNK LINO MAX
special grease at the base jaw lubrication
nipples by means of a grease gun.
8
8.1
8.2
8.3
8.4