Assembly and installation
34
01.00|PW V6 |en
Connecting ground cable
Ground connection
1
Screw
4
Toothed lock washer
2
Plain washer
5
Module
3
Cable lug
6
Ground marking
A ground connection must be established between the product
and the machine on the customer's premises.
The ground cable must be mounted on the threaded hole identi-
fied by the ground marking. If there no such threaded hole availa-
ble, mount the ground cable on another unused threaded hole on
the product.
NOTE
Do not mount the ground cable on a threaded hole that is already
used mechanically for something else, e.g. for screwing on an ac-
cessory.
Always mount the ground cable singly.
Always use all components of the screw connection and install
them in this order: plain washer, cable lug, and toothed lock
washer. See "Ground connection" diagram.