Technical data
26
3.00 | PRH | Assembly and Operating Manual | en | 389327
3.2 Factory settings / DEFAULT values
Reference value
DEFAULT value
Interface
USB
Baud rate
9600
Module address
11
3.3 Requirements for the voltage supply
NOTE
If the product is operated during a position run at high speed,
acceleration and jerk values, then voltage peaks in the power
supply may occur when delaying/braking due to the engine
recovering. The terminal voltage of the power supply can increase
via the output voltage of the power supply unit.
The power supply unit used for the power needs to be able to
handle this overvoltage and must not switch off its output voltage.
Otherwise, the product, for example, will stop with the error
message "ERROR_Motor_Voltage_LOW!" or
"ERROR_Motor_Voltage_High" which must be acknowledged.
Supply of the logic and power are to be separate. For this reason,
it is recommended that the product be connected in the following
way:
Ø
Connection of the logic supply of the product to a 24V power
supply unit.
Ø
Connection of the power supply of the product to a transformer
power supply unit or to a switching power supply unit.