![SCHUNK PLG 120 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/schunk/plg-120/plg-120_translation-of-original-operating-manual_1215993033.webp)
Assembly
6.4 Adjusting freely positionable end stops
When delivered, end stops are pre-assembled to the innermost or
outermost position possible. These can be adjusted to the desired
stroke-limiting positions.
In each mounting position, the stop (2) can be moved by
±12.5 mm.
Note:
End stops have to be positioned so that the movable stop of
the base jaw (4) strikes simultaneously on both sides.
Moving the freely positionable stop:
1. Loosen screws (1) and move stop (2) up to ±12.5 mm.
2. Tighten screws (1).
Offsetting the freely positionable stop:
1. Remove the screws (1).
2. Mount the stop (2) with screws (1) and shim (5) on the desired
hole (2).
3. Move stop (2) up to ±12.5 mm.
4. Tighten screws (1).
Screw tightening torques
Item Mounting
PLG
20
30
50
75
120
1
Thread
M6
M8
M10
DIN EN ISO 4762
Mounting screws according
to standard
Mounting screw strength
class
12.9
Max. tightening torque [Nm]
18
43
85
33