![SCHUNK PGN-plus-P Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/schunk/pgn-plus-p/pgn-plus-p_assembly-and-operating-manual_1215988042.webp)
Assembly
42
10.00 | PGN-plus-P | Assembly- and Operating Manual | en | 389753
Ø
Move product to the "gripper open" position.
Ø
Loosen clamping spindle (4) and remove the switching cam (6)
for inductive sensing from the base jaw by turning the adjusting
spindle (5).
Ø
Slide control cam (7) from the mounting kit into the base jaw.
✓
Darauf achten, dass die höhere Stirnseite der Schaltnocke (6)
nach außen zeigt.
Ø
Screw the switching cam (7) into the base jaw by turning the
adjusting spindle (5) until the adjustment dimension I3 is
reached
Setting dimensions for position sensors
30].
Ø
Fix the control cam (7) with the clamping spindle (4). It must not
be possible to move the control cam after assembly.
Ø
Slide the sensor (1) to the stop into the bracket (2).
Ø
Tighten the screw (3) on the bracket (2).
Tightening torque: 0.2 Nm
Ø
Connect the sensor, see assembly and operating manual of the
sensor.
Variant Dust-tight:
Screw in set-screw into the side cover.
5.4.13 Mount the flexible position sensor FPS
The flexible position sensor FPS consists of an evaluation unit and
one of the following sensors:
• MMS 22-A-5V
• FPS-S M8
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.