![SCHUNK PFH 30 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/schunk/pfh-30/pfh-30_assembly-and-operating-manual_1215971027.webp)
Maintenance and Care
08.01|PFH 30-50|en
27
Disassembly of the module
Version without gripping force maintenance device
Position of the position numbers
1 Remove all air feedings.
2 Unscrew the screws (29). Draw off the guiding strip (3) to-
gether with the cyl. pins (44) now.
3 Remove the cyl. pins (44), the screws (35) and the strip (13)
out of the guiding strip (3).
4 Turn the set-screws (38) back and remove the cover strips (42).
5 Remove the screws (32) and take off the cover plate (8).
6 Remove all screws (32) and take the piston (4) out of the housing.
7 After removal of the screws (46) take out the drivers (7), the
piston rod (5) and the assembly group consisting of the
toothed rod (2), intermediate piece (12) and the pressure strip
(18) out of the housing (1).
8 Remove the type lables by means of a screw driver or any sim-
ilar auxilliary.
9 Draw back the set-screws (9) back by 3 mm and take the
sleeves (6) out of the housing (1).
The gripper can be maintained now