Maintenance and repair work
108
06.00 | LDL | Assembly and Operation Manual | en | GAS341441
7.8 Limit switches and reference switches
Mechanical limit switches and inductive reference switch
1. Unscrew the mounting screws (1) of the switch baseplate (2)
2. Unscrew the mounting screws (3) of the switch (4 and 5) and
replace the switch
3. Install the new switch (4 and 5) and adjust the switching
distance to 0.5 mm.
4. Tighten the screws (1) on the switch (1) and carry out a test