Assembly and installation
38
05.00|EVG 55|en
The new firmware can be loaded on the module via the Motion Tool
Schunk software (MTS) (on the supplied DVD) under "Module" - "Up-
date firmware".
NOTE
For further information
☞
MotionToolSchunk.pdf document on the
DVD.
Procedure and requirements
DANGER
Danger due to faulty connection.
• Observe the pin assignment of the connecting terminals.
• Make sure that all components are grounded correctly.
Power supply (MCS-06)
24 V DC
Voltage supply of motor (gripper) 24 V DC (+ 10% / - 4%)
Voltage supply of logic
24 V DC (up to 36 V DC) ripple
smaller than 150 mVSS; switching
peak smaller than 240 mVSS
Connection value
Number of modules x nominal
module current x 1.2
Loading new firm-
ware on the module
5.4.4
Voltage supply requi-
rements