![SCHUNK EM310 W180 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/schunk/em310-w180/em310-w180_assembly-and-operating-manual_1215725014.webp)
Technical data
14
06.00 | RM-W | Assembly and Operating Manual | en | 389388
3 Technical data
Module type
RM50-310 W90
RM50-310 W180
Standard angle of rotation [°] *
90
180
End position adjustability [°]
± 5
Ambient temperature [°C]
5 - 60
IP rating
40
Noise emission [dB(A)]
≤ 70
Pressure medium
Compressed air, compressed air quality
according to ISO 8573-1:7 4 4
Min. pressure [bar]
3
Max. pressure [bar]
8
Nominal working pressure [bar]
6
* All other angles of rotation between 5 and 180 degrees can be
selected – specify when ordering –
☞
catalog.
More technical data is included in the catalog data sheet.
Whichever is the latest version.