General
8
02.00 | ELM | Assembly and operating manual | en | 389058
1.4.7 Anti-fall device
NOTICE
Damage to the rod lock due to incorrect actuation / overload!
•
The rod lock may only be triggered and unlocked when the
product has been shut down.
•
See the data on static holding force in the catalog. The forces
occurring in a clamped condition must not exceed the holding
force.
•
In the event of a dynamic load or overload (e.g. drop in
pressure during movement), the clamping cartridge must be
checked and replaced if necessary.
WARNING
The rod lock is not a safety component for personal protection
in the sense of the Machine Directive.
The module is optionally available with a rod lock to prevent
mechanical damage in the event of malfunctions.
Description
Type / ID
Rod lock for ELM 23-70
ASP-E 23-070 / 0314350
Rod lock for ELM 37-160
ASP-E 37-160 / 0314351
Rod lock for ELM 37-260
ASP-E 37 -260 / 0314352
1.4.8 Fan cooling
To increase the constant force in case of higher power con-
sumption.
Alternatively, cooling by means of compressed air is possi-ble, via
the connection provided.
Designation
Typ / ID
Fan cooling for ELM 23
MK 23 / 0314241
Fan cooling for ELM 37
MK 37 / 0314242
1.4.9 Cover
For routing of electric wires and pneumatic hoses
Designation
Typ / ID
Cover for ELM 23-70
MA 23-70 / 0314238
Cover for ELM 37-160
MA 37-160 / 0314239
Cover for ELM 37-260
MA 37-260 / 0314240