Design and description
26
05.00 | EGS | Assembly and Operating Manual | en | 389746
4.3.2 LED
Designation
Color
Function
READY
Green Indicates whether the voltage is connected.
•
Lights up
as long as voltage is present in the product.
•
Does not light up
if there is no voltage in the product.
ERROR
Red
Indicates whether there is a warning or an error.
•
Does not light up
when there is no warning or error and the
product is ready to operate.
•
Lights up
when there is an excessive temperature warning.
– The phase current of the motor is limited to I
duration
.
– The closing and opening times can increase.
– Is automatically extinguished when the warning no longer
exists.
•
Blinks slowly
(at approx. 1.2 s intervals) when there is an
excessive temperature warning.
– The product enters an idle phase until it has cooled down.
The commands "Open gripper", "Close gripper", "Rotate
counterclockwise" and "Rotate clockwise" are not
processed
– The error must be acknowledged.
•
Blinks rapidly
(at approx. 0.6 s intervals), when the "Gripping
force" rotary switch or swivel speed is between two switching
positions.
– Is automatically deleted when the "Gripping force" and
"Pivoting speed" rotary switches are on one switching
position.
Acknowledge error
1. Wait until the product has cooled down.
2. Actuate both digital inlets, PIN 2 and PIN 4, with high.
3. OR:
Disconnect voltage supply and reconnect.
✓
LED "error" is extinguished and the error is acknowledged.