Operation
8.2 Processing
DANGER
Flying workpiece due to insufficient clamping force during
machining, resulting from insufficient vacuum or excessive
machining forces.
Risk of injury or death due to flying workpiece
•
Monitor the vacuum value as close to the clamping location as
possible.
•
Wear personal protective clothing.
Processing steps in chronological order:
1. Place the workpiece on the Matrix-Plate.
2. Activate the vacuum using the manual slide valve. Support
suctioning of the workpiece, if necessary, by pressing it onto the
Matrix-Plate.
3. Check that the workpiece is securely held.
4. Start processing according to the machine specifications.
5. Once processing is complete, deactivate the vacuum using the
manual slide valve. The Matrix-Plate is vented automatically and
the workpiece can be removed.
To process workpieces on the complete machine, an operating
vacuum of at least -750 mbar is recommended. This is monitored
by the gauge. This does not mean that processing cannot also be
carried out at a lower vacuum level. To measure the vacuum, the
gauge must be connected directly to the Matrix-Plate.
Note:
A vacuum drop may cause the workpiece that is being machined
on the machine table to move or even be released.
Possible causes for a vacuum drop include:
• Power failure
• Sudden leakage
• Line break
• Malfunction
• Perforation in the workpiece due to machining
• Contaminated filter on the vacuum vent