Schumacher ProSeries 00-99-000686 Скачать руководство пользователя страница 1

THIS PRODUCT HAS A SEALED LEAD-ACID BATTERY INSIDE THAT SHOULD BE KEPT AT FULL CHARGE FOR LONGER LIFE.

RECHARGE WHEN FIRST RECEIVED, AFTER EACH USE AND EVERY 3 MONTHS.

IMPORTANT SAFETY INSTRUCTIONS

Save These Instructions

important safety instructions

Someone should be within range of your voice or close enough to 

come to your aid when you are working near a lead-acid battery.
Have  plenty  of  fresh  water  and  soap  nearby  in  case  battery  acid 

contacts skin, clothing, or eyes. If acid enters the eye area, rinse 

with  cold  water  for  at  least  10  minutes  and  get  medical  help 

immediately.
Do not smoke, or use matches or cigarette lighters, or allow any spark 

or flame near the battery or engine.

Never operate the power source unit if it has damaged lead wire or 

clamps. Have the lead wire replaced by a qualified technician.

Wear complete eye and clothing protection when working with lead-

acid batteries.
Do not permit internal battery in the jump starter to freeze. Never 

charge a frozen battery.

handling warning

WARNING:

 Handling the cord on this product or cords associated with 

this product, may expose you to lead, a chemical known to the State 

of California to cause cancer and birth defects or other reproductive 

harm. 

Wash hands after handling.

operating instructions

Warning:  Failure  to  follow  instructions  may  cause 
damage or an explosion. Read entire instruction manual 
before use.

1.  Turn ignition off before making cable connections.
2.  Use in a well-ventilated area.
3.  Keep clear of fan blades, belts, pulleys and other parts that may 

cause injury.

4.  Make sure the rotary power switch on the front panel is in the o 

(off) position until clamps are connected to the vehicle battery.

If plugged into an 110V AC wall outlet, disconnect.

5.  To prevent sparking, NEVER allow clamps to touch together or 

to contact the same piece of metal.

6.  Clamp the red clamp (+) to the positive terminal of the battery. 

(for a negative grounded system.)*

7.  Clamp the black clamp (-) to an unpainted and unmoving part 

of the chassis or engine block. The 3-digit display will show the 

voltage of the battery. 

8.  If you have connected the clamps backwards, an audio alarm 

will sound. Do NoT turn your jump starter on. This could cause 

serious damage. Reverse the connections, and the audio alarm 

will stop.

9.  If no audio alarm sounds, turn the rotary switch to the 12V position. 

(or, for Model PSJ-4424, switch to 12V or 24V.) The clamps are 

now powered. Crank the engine. If the engine does not start within 

5 – 8 seconds, stop cranking and wait at least 1 minute before 

attempting to start vehicle again. (This permits the battery to cool 

down.)

 

NOTE: 

When the voltage on the clips exceeds 15 volts, the audio 

alarm will beep four times. If the cables are connected to a 24-volt 

system when the switch is in the 12V position, the audio alarm 

will sound continuously. TURN off the jump starter immediately 

or internal battery damage will occur.

 

NOTE: 

If the switch is in the 12V or 24V position or the jump 

starter is connected to a battery for more than 5 minutes, four 

beeps will sound.  This is a reminder to turn the jump starter off 

and/or disconnect from battery when it is not in use.

10.  After the engine starts, turn the rotary switch to the o (off) 

position. Then disconnect the black clamp (-) and then the red 

clamp (+) in that order. Store the clamps in the compartments 

located on the sides of the case.

11.  Recharge the jump starter as soon as possible after use.
 

*NOTE:

  In  the  rare  case  of  jump-starting  a  vehicle  that  has 

a  positive-grounded  vehicle  electrical  system,  connect  the 

NEGATIVE  black  clamp  (-)  to  the  negative  terminal  (-)  of  the 

vehicle battery. Then connect the PoSITIVE red clamp (+) to an 

unpainted and unmoving part of the vehicle chassis or engine 

block. If you are unsure of the nature of the vehicle’s electrical 

grounding system, check the owner’s manual of the vehicle. To 

disconnect clamps, reverse order.

digitial display 

The  display  can  be  used  to  indicate  a  battery’s  voltage  when 

connected  to  a  battery  or  the  percentage  of  charge  in  the  jump 

starter’s internal battery.
With  the  switch  in  the  off  position,  connect  the  clamps  to  the 

vehicle’s battery and its voltage is displayed. Turn the jump starter’s 

rotary switch to 12V, (or, for Model PSJ-4424, 12V or 24V) and the 

combination of both internal and external batteries are shown.
To read the internal battery’s charge status: Press the display button 

to read the percentage of charge left in the internal battery. A fully 

charged battery will read 100%.

charging

  of  internal  battery  with  built-in  3-amp,  automatic 

charger.
After  removing  the  jump  starter  from  the  carton,  charge  it  for  a 

minimum of 8 hours before using.

1.  Make sure the rotary power switch on the front panel is in the o 

(off) position.

2.  Plug  extension  cord  into  charger  plug  on  the  left  side  of  the 

jump starter. (Extension cord not included; must be purchased 

separately.)

3.  Plug the extension cord into 110V AC electrical wall outlet.
4.  Charging of the internal battery could take up to 48 hours due to 

age and condition of the battery. At full charge, the charger will 

automatically drop into a float mode and maintain the battery at 

full charge without damaging the battery. The jump starter can 

be left plugged into the 110V wall outlet indefinitely to maintain 

full power.

00-99-000686/0906

InstRuctIon Manual

Jump starter & Dc Power source

Models:   PSJ-2212  One 22-Ah Battery   12V
 

PSJ-3612  Two 18-Ah Batteries  12V

 

PSJ-4424  Two 22-Ah Batteries  12/24V

Отзывы: